Literature DB >> 22763031

Novel multicompartment 3-dimensional radiochromic radiation dosimeters for nanoparticle-enhanced radiation therapy dosimetry.

Mamdooh Alqathami1, Anton Blencowe, Un Jin Yeo, Simon J Doran, Greg Qiao, Moshi Geso.   

Abstract

PURPOSE: Gold nanoparticles (AuNps), because of their high atomic number (Z), have been demonstrated to absorb low-energy X-rays preferentially, compared with tissue, and may be used to achieve localized radiation dose enhancement in tumors. The purpose of this study is to introduce the first example of a novel multicompartment radiochromic radiation dosimeter and to demonstrate its applicability for 3-dimensional (3D) dosimetry of nanoparticle-enhanced radiation therapy. METHODS AND MATERIALS: A novel multicompartment phantom radiochromic dosimeter was developed. It was designed and formulated to mimic a tumor loaded with AuNps (50 nm in diameter) at a concentration of 0.5 mM, surrounded by normal tissues. The novel dosimeter is referred to as the Sensitivity Modulated Advanced Radiation Therapy (SMART) dosimeter. The dosimeters were irradiated with 100-kV and 6-MV X-ray energies. Dose enhancement produced from the interaction of X-rays with AuNps was calculated using spectrophotometric and cone-beam optical computed tomography scanning by quantitatively comparing the change in optical density and 3D datasets of the dosimetric measurements between the tissue-equivalent (TE) and TE/AuNps compartments. The interbatch and intrabatch variability and the postresponse stability of the dosimeters with AuNps were also assessed.
RESULTS: Radiation dose enhancement factors of 1.77 and 1.11 were obtained using 100-kV and 6-MV X-ray energies, respectively. The results of this study are in good agreement with previous observations; however, for the first time we provide direct experimental confirmation and 3D visualization of the radiosensitization effect of AuNps. The dosimeters with AuNps showed small (<3.5%) interbatch variability and negligible (<0.5%) intrabatch variability.
CONCLUSIONS: The SMART dosimeter yields experimental insights concerning the spatial distributions and elevated dose in nanoparticle-enhanced radiation therapy, which cannot be performed using any of the current methods. The authors concluded that it can be used as a novel independent method for nanoparticle-enhanced radiation therapy dosimetry.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22763031     DOI: 10.1016/j.ijrobp.2012.05.029

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  4 in total

Review 1.  Detection of therapeutic radiation in three-dimensions.

Authors:  John A Adamovics
Journal:  Beilstein J Org Chem       Date:  2017-07-05       Impact factor: 2.883

2.  Evaluation of Gold Nanoparticle Size Effect on Dose Enhancement Factor in Megavoltage Beam Radiotherapy Using MAGICA Polymer Gel Dosimeter.

Authors:  Zh Behrouzkia; R Zohdiaghdam; H R Khalkhali; F Mousavi
Journal:  J Biomed Phys Eng       Date:  2019-02-01

3.  Optimal energy for cell radiosensitivity enhancement by gold nanoparticles using synchrotron-based monoenergetic photon beams.

Authors:  Wan Nordiana Rahman; Stéphanie Corde; Naoto Yagi; Siti Aishah Abdul Aziz; Nathan Annabell; Moshi Geso
Journal:  Int J Nanomedicine       Date:  2014-05-19

Review 4.  The Basic Properties of Gold Nanoparticles and their Applications in Tumor Diagnosis and Treatment.

Authors:  Xue Bai; Yueying Wang; Zhiyun Song; Yanmin Feng; Yuanyuan Chen; Deyuan Zhang; Lin Feng
Journal:  Int J Mol Sci       Date:  2020-04-03       Impact factor: 5.923

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.