Time and temperature stability of T-cell subsets evaluated by a dual-platform method.

Horatiu Olteanu, Bernard C Schur, Alexandra M Harrington, Steven H Kroft.   

Abstract

INTRODUCTION: T-cell subset enumeration in HIV patients is routinely performed for monitoring infection stage and response to antiretroviral therapy. Studies have examined the effect of specimen refrigeration and age for single-platform (SP) methods, but there is limited data for time and temperature requirements of dual-platform (DP) methods.
METHODS: Using a DP method, we analyzed peripheral blood (PB) from 52 HIV patients at room temperature (RT) at 24, 72, and 96 hours. PBs from 34 HIV patients had baseline RT analysis within 24 hours, and then were refrigerated and analyzed at 24, 48, and 72 hours. The coefficient of variation (CV) and residuals (changes in lymphocyte subsets) were recorded at each time point and compared to assess the precision and bias under the various conditions. Testing performance under different conditions was compared by linear regression.
RESULTS: Mean CV was ≤7.3% and median residuals were <30/μl for absolute CD4 and CD8 determinations. There was good correlation between baseline analysis data at RT and at various time points, both at RT and 4°C.
CONCLUSIONS: Our results are similar to those published for SP methods for aging or refrigerated specimens. The high level of agreement between measurements supports the robustness of this DP methodology.

Entities:  

Keywords:  Absolute CD4 counts; HIV; dual platform; flow cytometry; specimen stability

Year:  2012        PMID: 22762032      PMCID: PMC3384401     

Source DB:  PubMed          Journal:  Am J Blood Res        ISSN: 2160-1992


  13 in total

1.  Absolute CD4+ T-lymphocyte and CD34+ stem cell counts by single-platform flow cytometry: the way forward.

Authors:  D Barnett; V Granger; L Whitby; I Storie; J T Reilly
Journal:  Br J Haematol       Date:  1999-09       Impact factor: 6.998

2.  Multisite comparison of CD4 and CD8 T-lymphocyte counting by single- versus multiple-platform methodologies: evaluation of Beckman Coulter flow-count fluorospheres and the tetraONE system. The NIAID DAIDS New Technologies Evaluation Group.

Authors:  K A Reimann; M R O'Gorman; J Spritzler; C L Wilkening; D E Sabath; K Helm; D E Campbell
Journal:  Clin Diagn Lab Immunol       Date:  2000-05

3.  Evaluation of TruCount absolute-count tubes for determining CD4 and CD8 cell numbers in human immunodeficiency virus-positive adults. Site Investigators and The NIAID DAIDS New Technologies Evaluation Group.

Authors:  C T Schnizlein-Bick; J Spritzler; C L Wilkening; J K Nicholson; M R O'Gorman
Journal:  Clin Diagn Lab Immunol       Date:  2000-05

4.  Affordable CD4(+) T-cell counts on 'single-platform' flow cytometers I. Primary CD4 gating.

Authors:  G Janossy; I Jani; W Göhde
Journal:  Br J Haematol       Date:  2000-12       Impact factor: 6.998

5.  Use of CD45 gating in three and four-color flow cytometric immunophenotyping: guideline from the National Institute of Allergy and Infectious Diseases, Division of AIDS.

Authors:  Carol T Schnizlein-Bick; Francis F Mandy; Maurice R G O'Gorman; Helene Paxton; Janet K A Nicholson; Lance E Hultin; Rebecca S Gelman; Cynthia L Wilkening; Daniella Livnat
Journal:  Cytometry       Date:  2002-04-15

6.  Guidelines for performing single-platform absolute CD4+ T-cell determinations with CD45 gating for persons infected with human immunodeficiency virus. Centers for Disease Control and Prevention.

Authors:  Francis F Mandy; Janet K A Nicholson; J Steven McDougal
Journal:  MMWR Recomm Rep       Date:  2003-01-31

7.  Acquired immune dysfunction in homosexual men: immunologic profiles.

Authors:  A J Ammann; D Abrams; M Conant; D Chudwin; M Cowan; P Volberding; B Lewis; C Casavant
Journal:  Clin Immunol Immunopathol       Date:  1983-06

Review 8.  CD4 immunophenotyping in HIV infection.

Authors:  David Barnett; Brooke Walker; Alan Landay; Thomas N Denny
Journal:  Nat Rev Microbiol       Date:  2008-11       Impact factor: 60.633

9.  Selection of lymphocyte gating protocol has an impact on the level of reliability of T-cell subsets in aging specimens.

Authors:  M Bergeron; J K A Nicholson; S Phaneuf; T Ding; N Soucy; A D Badley; N C Hawley Foss; F Mandy
Journal:  Cytometry       Date:  2002-04-15

10.  The prognostic value of cellular and serologic markers in infection with human immunodeficiency virus type 1.

Authors:  J L Fahey; J M Taylor; R Detels; B Hofmann; R Melmed; P Nishanian; J V Giorgi
Journal:  N Engl J Med       Date:  1990-01-18       Impact factor: 91.245

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.