Literature DB >> 22760507

Direct and quantitative analysis of underivatized acylcarnitines in serum and whole blood using paper spray mass spectrometry.

Qian Yang1, Nicholas E Manicke, He Wang, Christopher Petucci, R Graham Cooks, Zheng Ouyang.   

Abstract

A simple protocol for rapid quantitation of acylcarnitines in serum and whole blood has been developed using paper spray mass spectrometry. Dried serum and whole blood containing a mixture of ten acylcarnitines at various concentrations were analyzed as spots from paper directly without any sample pretreatment, separation, or derivatization. The composition of the spray solvent was found to be a critical factor: for serum samples, spray solvent of methanol/water/formic acid (80:20:0.1) gave the best signal intensity while for blood samples which contain more matrix components, acetonitrile/water (90:10) was a much more suitable spray solvent. For the paper type and size used, 0.5 μL of sample provided an optimal signal for both serum and whole blood samples. For quantitative profiling, the limits of quantitation obtained from both serum and blood were much lower than the clinically validated cutoff values for diagnosis of fatty acid oxidation disorders in newborn screening. Linearity (R(2) > 0.95) and reproducibility (RSD ~10 %) were achieved in the concentration ranges from 100 nM to 5 μM for the C2 acylcarnitine, and for other acylcarnitines, these values were from 10 to 500 nM. Acylcarnitine profiles offer an effective demonstration of the fact that paper spray mass spectrometry is an appropriate, simple, rapid method with high sensitivity and high reproducibility applicable to newborn screening tests.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22760507      PMCID: PMC3598621          DOI: 10.1007/s00216-012-6211-4

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  40 in total

Review 1.  Diagnosis and management of defects of mitochondrial beta-oxidation.

Authors:  Jerry Vockley; Rani H Singh; David A H Whiteman
Journal:  Curr Opin Clin Nutr Metab Care       Date:  2002-11       Impact factor: 4.294

2.  Quantitative analysis of therapeutic drugs in dried blood spot samples by paper spray mass spectrometry: an avenue to therapeutic drug monitoring.

Authors:  Nicholas Edward Manicke; Paul Abu-Rabie; Neil Spooner; Zheng Ouyang; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2011-06-21       Impact factor: 3.109

3.  Application of fast atom bombardment with tandem mass spectrometry and liquid chromatography/mass spectrometry to the analysis of acylcarnitines in human urine, blood, and tissue.

Authors:  D S Millington; D L Norwood; N Kodo; C R Roe; F Inoue
Journal:  Anal Biochem       Date:  1989-08-01       Impact factor: 3.365

4.  Electrospray-assisted laser desorption/ionization mass spectrometry for direct ambient analysis of solids.

Authors:  Jentaie Shiea; Min-Zon Huang; Hsiu-Jung Hsu; Chi-Yang Lee; Cheng-Hui Yuan; Iwona Beech; Jan Sunner
Journal:  Rapid Commun Mass Spectrom       Date:  2005       Impact factor: 2.419

5.  Prenatal diagnosis of mitochondrial fatty acid oxidation defects.

Authors:  M A Nada; C Vianey-Saban; C R Roe; J H Ding; M Mathieu; R S Wappner; M G Bialer; J A McGlynn; G Mandon
Journal:  Prenat Diagn       Date:  1996-02       Impact factor: 3.050

6.  Established and emerging atmospheric pressure surface sampling/ionization techniques for mass spectrometry.

Authors:  Gary J Van Berkel; Sofie P Pasilis; Olga Ovchinnikova
Journal:  J Mass Spectrom       Date:  2008-09       Impact factor: 1.982

7.  Diagnosis of inborn errors of metabolism by acylcarnitine profiling in blood using tandem mass spectrometry.

Authors:  C Vianey-Saban; N Guffon; F Delolne; P Guibaud; M Mathieu; P Divry
Journal:  J Inherit Metab Dis       Date:  1997-07       Impact factor: 4.982

8.  Newborn screening by tandem mass spectrometry (MS-MS)

Authors:  L Sweetman
Journal:  Clin Chem       Date:  1996-03       Impact factor: 8.327

9.  Application of high resolution fast atom bombardment and constant B/E ratio linked scanning to the identification and analysis of acylcarnitines in metabolic disease.

Authors:  D S Millington; C R Roe; D A Maltby
Journal:  Biomed Mass Spectrom       Date:  1984-05

10.  Newborn screening: toward a uniform screening panel and system.

Authors: 
Journal:  Genet Med       Date:  2006-05       Impact factor: 8.822

View more
  19 in total

1.  Ambient Ionization Mass Spectrometry Measurement of Aminotransferase Activity.

Authors:  Xin Yan; Xin Li; Chengsen Zhang; Yang Xu; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2017-01-31       Impact factor: 3.109

2.  Quantitation of Fentanyl Analogs in Dried Blood Spots by Flow-Through Desorption Coupled to Online Solid Phase Extraction Tandem Mass Spectrometry.

Authors:  Rebecca L Shaner; Nicholas D Schulze; Craig Seymour; Elizabeth I Hamelin; Jerry D Thomas; Rudolph C Johnson
Journal:  Anal Methods       Date:  2017-06-16       Impact factor: 2.896

3.  Separation of opiate isomers using electrospray ionization and paper spray coupled to high-field asymmetric waveform ion mobility spectrometry.

Authors:  Nicholas E Manicke; Michael Belford
Journal:  J Am Soc Mass Spectrom       Date:  2015-03-24       Impact factor: 3.109

4.  Ambient ionization and miniature mass spectrometry system for chemical and biological analysis.

Authors:  Xiaoxiao Ma; Zheng Ouyang
Journal:  Trends Analyt Chem       Date:  2016-12       Impact factor: 12.296

5.  Simultaneous quantitation of five triazole anti-fungal agents by paper spray-mass spectrometry.

Authors:  Christine L Skaggs; Greta J Ren; El Taher M Elgierari; Lillian R Sturmer; Run Z Shi; Nicholas E Manicke; Lindsey M Kirkpatrick
Journal:  Clin Chem Lab Med       Date:  2020-04-28       Impact factor: 3.694

6.  Characterization and Analysis of Paper Spray Ionization of Organic Compounds.

Authors:  Hugo Aliaga-Aguilar
Journal:  J Am Soc Mass Spectrom       Date:  2017-10-16       Impact factor: 3.109

7.  Clinical Application of Ambient Ionization Mass Spectrometry.

Authors:  Li-Hua Li; Hua-Yi Hsieh; Cheng-Chih Hsu
Journal:  Mass Spectrom (Tokyo)       Date:  2017-02-24

8.  Studying reaction intermediates formed at graphenic surfaces.

Authors:  Depanjan Sarkar; Soujit Sen Gupta; Rahul Narayanan; Thalappil Pradeep
Journal:  J Am Soc Mass Spectrom       Date:  2014-01-03       Impact factor: 3.109

9.  Development of miniature mass spectrometry systems for bioanalysis outside the conventional laboratories.

Authors:  Xiaoyu Zhou; Jiangjiang Liu; Robert Graham Cooks; Zheng Ouyang
Journal:  Bioanalysis       Date:  2014-06       Impact factor: 2.681

10.  Quantitative paper spray mass spectrometry analysis of drugs of abuse.

Authors:  Yuan Su; He Wang; Jiangjiang Liu; Pu Wei; R Graham Cooks; Zheng Ouyang
Journal:  Analyst       Date:  2013-06-18       Impact factor: 4.616

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.