Literature DB >> 22758923

The Florida Shock Anxiety Scale (FSAS) for patients with implantable cardioverter defibrillators: testing factor structure, reliability, and validity of a previously established measure.

Jessica Ford1, John F Finch, Lawrence K Woodrow, Katherine E Cutitta, Julie Shea, Avi Fischer, Garrett Hazelton, Samuel F Sears.   

Abstract

BACKGROUND: The implantable cardioverter defibrillator (ICD) reduces mortality in patients at risk for life-threatening arrhythmias via high energy shock. The Florida Shock Anxiety Scale (FSAS) was developed to measure ICD patient shock-related anxiety. Initial psychometric evaluation revealed good reliability and validity. The purpose of this study was to examine the psychometrics of the FSAS in a large US sample of ICD patients.
METHODS: Participants were recruited via e-mail and the survey was completed online. Ultimately, 443 ICD patients (359 male and 421 White) completed the 10-item FSAS.
RESULTS: Means for FSAS were comparable to previously published data (M = 15.18, SD = 6.5). Interitem reliability was good (Cronbach's α= 0.89). The FSAS was negatively correlated with single-item measures of emotional well-being (r =-0.378, P < 0.01), sense of security (r =-0.365, P < 0.01), perceived general health (r =-0.185, P < 0.01), and quality of life (r =-0.216, P < .01), demonstrating discriminant validity. Convergent validity was supported through significant correlations with number of shocks (r = 0.464, P < 0.01) and reported disruptiveness of shock (r = 0.484, P < 0.01). Confirmatory factor analysis revealed that a single (second-order) factor model (χ(2) [34] = 75.34, P < 0.05, comparative fit index = 0.98, root mean-square error of approximation = 0.05) had the best fit.
CONCLUSIONS: Shock anxiety as a construct can be measured in a reliable and valid method by the FSAS. These nationally representative data suggest that a single score for shock anxiety is an easy to use and appropriate method of assessment. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22758923     DOI: 10.1111/j.1540-8159.2012.03455.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  8 in total

1.  Cognitive performance in patients with implantable cardioverter defibrillators: Associations with objective sleep duration, age and anxiety.

Authors:  Ashley F Curtis; Alicia J Roth; Samuel F Sears; Jamie B Conti; Richard B Berry; Joseph M Dzierzewski; Himangshu Rathinakumar; Christina S McCrae
Journal:  J Sleep Res       Date:  2018-12-13       Impact factor: 3.981

2.  Age, Sex, and Remote Monitoring Differences in Device Acceptance for Patients With Implanted Cardioverter Defibrillators in Canada.

Authors:  Jessica Ng; Samuel F Sears; Derek V Exner; Lucy Reyes; Xenia Cravetchi; Peggy Cassidy; James Morton; Carmen Lohrenz; Aaron Low; Roopinder K Sandhu; Robert S Sheldon; Satish R Raj
Journal:  CJC Open       Date:  2020-06-16

3.  Sleep, Psychosocial Functioning, and Device-Specific Adjustment in Patients with Implantable Cardioverter Defibrillators (ICDs).

Authors:  Christina S McCrae; Alicia J Roth; Jessica Ford; Earl C Crew; Jamie B Conti; Richard B Berry; Samuel F Sears
Journal:  Behav Sleep Med       Date:  2014-08-30       Impact factor: 2.964

Review 4.  Assessment of patient-reported symptoms of anxiety.

Authors:  Matthias Rose; Janine Devine
Journal:  Dialogues Clin Neurosci       Date:  2014-06       Impact factor: 5.986

5.  Prevalence of anxiety in patients with an implantable cardioverter defibrillator: measurement equivalence of the HADS-A and the STAI-S.

Authors:  W H Emons; M Habibović; S S Pedersen
Journal:  Qual Life Res       Date:  2019-06-22       Impact factor: 4.147

6.  Remote-only monitoring for patients with cardiac implantable electronic devices: a before-and-after pilot study.

Authors:  John A Sapp; Anne M Gillis; Amir AbdelWahab; Isabelle Nault; Pablo B Nery; Jeff S Healey; Satish R Raj; Evan Lockwood; Laurence D Sterns; Samuel F Sears; George A Wells; Raymond Yee; François Philippon; Anthony Tang; Ratika Parkash
Journal:  CMAJ Open       Date:  2021-01-25

7.  Synergistic application of cardiac sympathetic decentralization and comprehensive psychiatric treatment in the management of anxiety and electrical storm.

Authors:  Sahib S Khalsa; Leila Shahabi; Olujimi A Ajijola; Alexander Bystritsky; Bruce D Naliboff; Kalyanam Shivkumar
Journal:  Front Integr Neurosci       Date:  2014-01-02

8.  Patients With Implantable Cardioverter Defibrillators on Social Media Report More Shock Anxiety Than Clinic Patients: Results From an Online Survey.

Authors:  Linda Kramer Freeman; Keith Richards; Jamie B Conti; Samuel F Sears
Journal:  JMIR Cardio       Date:  2017-09-26
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.