Literature DB >> 22749755

Asynchronies and sleep disruption in neuromuscular patients under home noninvasive ventilation.

Grazia Crescimanno1, Maria Canino, Oreste Marrone.   

Abstract

BACKGROUND: Noninvasive ventilation (NIV) may improve quality of sleep but patient-ventilator asynchronies (PVA) may affect sleep structure. Possible changes in ventilation quality after hospital discharge are poorly known.
OBJECTIVE: To analyse the impact of different kinds of PVA on sleep disruption in chronically ventilated neuromuscular patients after in-hospital optimization of ventilator setting with nocturnal polygraphy, and to compare home and hospital PVA occurrence.
METHODS: Eighteen patients were included in the study. PVA during hospital polygraphic monitoring and during successive home polysomnography were analysed. The relationships between PVA and air leaks, sleep stages, and arousals or awakenings recorded during polysomnography were investigated.
RESULTS: Overall, PVA had a low rate of occurrence (4.32 events/h, IQR 1.75-6.25), but their number was higher during home polysomnographies than in hospital (p = 0.0039): their increase was correlated to an increase in air leaks with respect to hospital monitorings (p = 0.020). Autotriggerings were the most common asynchronies, followed by ineffective efforts (IE) and prolonged insufflations (PI). All asynchronies occurred more often in NREM than in REM sleep. Autotriggerings and IE were more often associated with arousals than PI (p < 0.05). PVA rate was correlated with arousals and awakenings rate (r = 0.49, p = 0.03), but, due to the low PVA rate, only 12.69% of arousals and awakenings were associated with PVA.
CONCLUSIONS: Most kinds of PVA are often associated with arousals. Polygraphic monitoring may help to improve ventilator setting. However, air leaks and autotriggerings may increase in unassisted environments. Therefore, it may be useful to extend control of NIV effects at home.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22749755     DOI: 10.1016/j.rmed.2012.05.013

Source DB:  PubMed          Journal:  Respir Med        ISSN: 0954-6111            Impact factor:   3.415


  7 in total

Review 1.  Sleep-disordered breathing in patients with neuromuscular disease.

Authors:  Mohamad Ammar Albdewi; Giuseppe Liistro; Riëm El Tahry
Journal:  Sleep Breath       Date:  2017-07-12       Impact factor: 2.816

Review 2.  Patient ventilator asynchrony and sleep disruption during non-invasive ventilation.

Authors:  Michelle Ramsay
Journal:  J Thorac Dis       Date:  2018-01       Impact factor: 2.895

Review 3.  Monitoring Long Term Noninvasive Ventilation: Benefits, Caveats and Perspectives.

Authors:  Jean-Paul Janssens; Chloé Cantero; Patrick Pasquina; Marjolaine Georges; Claudio Rabec
Journal:  Front Med (Lausanne)       Date:  2022-05-19

4.  Noninvasive ventilation improves sleep in amyotrophic lateral sclerosis: a prospective polysomnographic study.

Authors:  Bart Vrijsen; Bertien Buyse; Catharina Belge; Wim Robberecht; Philip Van Damme; Marc Decramer; Dries Testelmans
Journal:  J Clin Sleep Med       Date:  2015-04-15       Impact factor: 4.062

5.  Combined effects of leaks, respiratory system properties and upper airway patency on the performance of home ventilators: a bench study.

Authors:  Kaixian Zhu; Claudio Rabec; Jésus Gonzalez-Bermejo; Sébastien Hardy; Sami Aouf; Pierre Escourrou; Gabriel Roisman
Journal:  BMC Pulm Med       Date:  2017-11-21       Impact factor: 3.317

6.  Flow and airway pressure analysis for detecting ineffective effort during mechanical ventilation in neuromuscular patients.

Authors:  Cristina Ciorba; Jesus Gonzalez-Bermejo; Maria-Antonia Quera Salva; Djillali Annane; David Orlikowski; Frédéric Lofaso; Hélène Prigent
Journal:  Chron Respir Dis       Date:  2018-07-31       Impact factor: 2.444

7.  Sleep increases leaks and asynchronies during home noninvasive ventilation: a polysomnographic study.

Authors:  Sergi Martí; Alex Ferré; Gabriel Sampol; Mercedes Pallero; Odile Romero; Jaume Ferrer; Júlia Sampol
Journal:  J Clin Sleep Med       Date:  2022-01-01       Impact factor: 4.062

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.