Literature DB >> 22745117

Are central venous lactate and arterial lactate interchangeable? A human retrospective study.

François Réminiac1, Christophe Saint-Etienne, Isabelle Runge, Denis Ykpé Ayé, Dalila Benzekri-Lefevre, Armelle Mathonnet, Thierry Boulain.   

Abstract

BACKGROUND: In critically ill patients, arterial blood lactate concentration (Lact(a)) and Lact(a) clearance are used for the diagnosis of shock, for prognosis assessment, and to guide therapy. In recent years, central venous oxygen saturation (ScvO(2)), a surrogate for mixed venous blood saturation, either measured by fiberoptic catheters or from central venous blood samples, was used in shock to estimate the global balance between oxygen delivery and consumption. When central venous blood is drawn for ScvO(2) measurement, it also could be used to measure central venous lactate concentration (Lact(cv)). In this study, we evaluated the utility of Lact(cv) and Lact(cv) clearance as predictors of Lact(a) and Lact(a) clearance, respectively, in critically ill patients.
METHODS: This retrospective study was performed in an intensive care unit of a regional and teaching hospital. Using the electronic registry of our blood gas analyzer from March 2007 to December 2009, we identified patients with circulatory or respiratory failure who had pairs of Lact(cv) and Lact(a) obtained within a 30-minute interval. To assess the utility of Lact(cv) as a predictor of Lact(a) above 2 and 4 mmol/L, we calculated the area under receiver operating characteristic curves (AUCs) for these thresholds. We also calculated AUC of Lact(cv) clearance to detect a Lact(a) clearance <10% or >10%.
RESULTS: Six hundred seventy-three Lact(cv)/Lact(a) pairs in 188 patients were analyzed. AUC of Lact(cv) to predict a Lact(a) above 2 and 4 mmol/L was 0.98 (95% confidence interval: 0.97-0.99) and 0.98 (95% confidence interval: 0.96-0.99), respectively. Lact(cv) with the cutoff value of 2 mmol/L can predict a Lact(a) above 2 mmol/L with sensitivity >92% and specificity >90%. AUC for Lact(cv) clearance to detect a Lact(a) clearance <10% or >10% was 0.93 or 0.94, respectively.
CONCLUSION: Lact(cv) and Lact(a) collected within a 30-minute range are interchangeable for clinical practice.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22745117     DOI: 10.1213/ANE.0b013e31825e703e

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  8 in total

1.  Hyperlactatemia on ICU admission : Comparison between direct admissions and inpatient transfers.

Authors:  A F Peschka; S Kaestle; F Seidel; L Weidhase; M Bernhard; A Gries; S Petros
Journal:  Med Klin Intensivmed Notfmed       Date:  2018-07-26       Impact factor: 0.840

2.  The effect of CPAP treatment on venous lactate and arterial blood gas among obstructive sleep apnea syndrome patients.

Authors:  Ting Lin; Jie-Feng Huang; Qi-Chang Lin; Gong-Ping Chen; Bi-Ying Wang; Jian-Ming Zhao; Jia-Chao Qi
Journal:  Sleep Breath       Date:  2016-09-29       Impact factor: 2.816

3.  Refractory Lactic Acidosis and an Approach to its Management - A Case Report.

Authors:  Yingke He; John Ong; Sharon Ong
Journal:  J Crit Care Med (Targu Mures)       Date:  2019-05-13

4.  Assessing lactate concentration as a predictor of 28-day in-hospital mortality in the presence of ethanol: A retrospective study of emergency department patients.

Authors:  Arvin Radfar Akhavan; Nicholas J Johnson; Benjamin Friedman; Jane Hall; Karl Jablonowski; M Kennedy Hall; Daniel J Henning
Journal:  J Am Coll Emerg Physicians Open       Date:  2021-03-02

5.  Peripheral venous lactate levels substitute arterial lactate levels in the emergency department.

Authors:  Yasufumi Oi; Kosuke Mori; Hidehiro Yamagata; Ayako Nogaki; Tomoaki Takeda; Chikara Watanabe; Yusuke Sakaguchi; Fumihiro Ogawa; Takeru Abe; Shouhei Imaki; Ichiro Takeuchi
Journal:  Int J Emerg Med       Date:  2022-01-28

6.  Evaluation of adjusted central venous blood gases versus arterial blood gases of patients in post-operative paediatric cardiac surgical intensive care unit.

Authors:  Naveen G Singh; S R Prasad; V Manjunath; P S Nagaraja; Pranav J Adoni; Divya Gopal; A M Jagadeesh
Journal:  Indian J Anaesth       Date:  2015-10

Review 7.  Use of femoral vein catheters for the assessment of perfusion parameters.

Authors:  Yara Nishiyama Marti; Flávia Ribeiro Machado
Journal:  Rev Bras Ter Intensiva       Date:  2013 Apr-Jun

8.  Is venous blood drawn from femoral access adequate to estimate the central venous oxygen saturation and arterial lactate levels in critically ill patients?

Authors:  Yara Nishiyama Marti; Flávio Geraldo Rezende de Freitas; Rodrigo Palácio de Azevedo; Milena Leão; Antônio Tonete Bafi; Flavia Ribeiro Machado
Journal:  Rev Bras Ter Intensiva       Date:  2015 Oct-Dec
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.