Literature DB >> 22744497

An improved kinematic model of the spine for three-dimensional motion analysis in the Vicon system.

Mirosława M Długosz1, Daria Panek, Paweł Maciejasz, Wiesław Chwała, Witold Alda.   

Abstract

The mechanism of creation and pathomechanics of lateral spinal deformation is still not fully explained. Modern medical imaging techniques give scientists possibility to understand some aspects, but vast majority of those techniques is based on static trials. A motion capture system belongs to techniques which enable visualization of a spine during dynamic trials; however, due to lack of appropriate computational model, it is unsuitable for scoliosis imaging. A few years ago our group has proposed a kinematic model of the spine to be used with Vicon Motion Capture System, which was based on Bézier curves. That model allowed for much more precise investigation of spinal kinematics during dynamic trials as compared with other computational models. However, it did not allowed to restrict only selected movements for particular segments of the spine (e.g. axial rotation for lumbar spine). The aim of the current work is to improve the proposed model in order to be able to restrict selected movements according to the knowledge concerning spinal anatomy and spinal range of motion. The new kinematic model of the spine was written in BodyBuilder for Biomechanics Language. For the purpose of visualization also an accurate graphical representation of each vertebra (polygon mesh) was computed and adapted to be compatible with the kinematic model. Using a new version of the model it is possible to perform precise analysis of movement of all vertebrae during such dynamic activities as e.g. gait and forward or lateral bending, as well as to present the results not only on the charts, but also as a 3D animation of movements of a realistically looking spine. The paper describes the new kinematic model and the process of creating graphical representation of the vertebrae. Also sample results obtained using that model are presented.

Entities:  

Mesh:

Year:  2012        PMID: 22744497

Source DB:  PubMed          Journal:  Stud Health Technol Inform        ISSN: 0926-9630


  2 in total

1.  Assessing the accuracy of measuring leg length discrepancy and genu varum/valgum using a markerless motion analysis system.

Authors:  Robert J Hurley; Martin S Davey; Micheal Newell; Aiden Devitt
Journal:  J Orthop       Date:  2021-07-13

2.  Medical work assessment in German hospitals: a study protocol of a movement sequence analysis (MAGRO-MSA).

Authors:  Daniela Ohlendorf; Mario Schwarzer; Julia Rey; Ingo Hermanns; Albert Nienhaus; Rolf Ellegast; Dirk Ditchen; Stefanie Mache; David A Groneberg
Journal:  J Occup Med Toxicol       Date:  2015-01-09       Impact factor: 2.646