Literature DB >> 22744294

The type of mat (Contact vs. Photocell) affects vertical jump height estimated from flight time.

Juan García-López1, Juan C Morante, Ana Ogueta-Alday, Jose A Rodríguez-Marroyo.   

Abstract

The purposes of this study were to analyze the validity and reliability of 2 photocell mats and to probe the possible influence of the type of mat (contact vs. photocell) on vertical jump height estimated from flight time. In 2 separate studies, 89 and 92 physical students performed 3 countermovement jumps that were simultaneously registered by a Force Plate (gold standard method), 2 photocell mats (SportJump System Pro and ErgoJump Plus), and a contact mat (SportJump-v1.0). The first study showed that the 2 photocell mats underestimated the vertical jump height (1.3 ± 0.2 cm and 5.9 ± 5.2 cm, respectively), but only SportJump System Pro showed a high correlation with the Force Plate (r = 0.999 and 0.676, respectively) and good intraday reliability (coefficient of variation = 2.98 and 15.94%, intraclass correlation coefficients = 0.95-0.97 and 0.45-0.57, respectively). The second study demonstrated a strong correlation (r = 0.994) between the 2 technologies (contact vs. photocell mats) with differences in vertical jump height of 2.0 ± 0.8 cm (95% confidence interval = 1.9-2.1 cm), which depended on both flight time and subjects' body mass. In conclusion, SportJump System Pro was a valid and reliable device. The new devices to measure vertical jump height from flight time should be validated. The type of mat (contact vs. photocell) affected approximately 6% the vertical jump height (approximately 2 cm in this study), which should be considered in further studies. The use of validated photocell mats instead of the contact mats was recommended.

Mesh:

Year:  2013        PMID: 22744294     DOI: 10.1519/JSC.0b013e31826520d7

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  8 in total

Review 1.  A brief review of strength and ballistic assessment methodologies in sport.

Authors:  Daniel Travis McMaster; Nicholas Gill; John Cronin; Michael McGuigan
Journal:  Sports Med       Date:  2014-05       Impact factor: 11.136

2.  Concurrent Validity and Test-retest Reliability of the OPTOGait Photoelectric Cell System for the Assessment of Spatio-temporal Parameters of the Gait of Young Adults.

Authors:  Myung Mo Lee; Chang Ho Song; Kyoung Jin Lee; Sang Woo Jung; Doo Chul Shin; Seung Ho Shin
Journal:  J Phys Ther Sci       Date:  2014-02-06

3.  Validity Study of a Jump Mat Compared to the Reference Standard Force Plate.

Authors:  Slavko Rogan; Lorenz Radlinger; Caroline Imhasly; Andrea Kneubuehler; Roger Hilfiker
Journal:  Asian J Sports Med       Date:  2015-12-01

4.  Assessing Reactive Strength Measures in Jumping and Hopping Using the Optojump™ System.

Authors:  Robin Healy; Ian C Kenny; Andrew J Harrison
Journal:  J Hum Kinet       Date:  2016-12-15       Impact factor: 2.193

5.  Differences in Vertical Jump Force-Time Characteristics between Stronger and Weaker Adolescent Basketball Players.

Authors:  Christopher Thomas; Irene Kyriakidou; Thomas Dos'Santos; Paul A Jones
Journal:  Sports (Basel)       Date:  2017-08-24

6.  Validity and reliability of the WIMU inertial device for the assessment of the vertical jump.

Authors:  José Pino-Ortega; Javier García-Rubio; Sergio J Ibáñez
Journal:  PeerJ       Date:  2018-04-30       Impact factor: 2.984

7.  A Wearable System for Jump Detection in Inline Figure Skating.

Authors:  Antonio Panfili; Alvise Spanò; Agostino Cortesi
Journal:  Sensors (Basel)       Date:  2022-02-20       Impact factor: 3.576

Review 8.  How to Improve the Reactive Strength Index among Male Athletes? A Systematic Review with Meta-Analysis.

Authors:  André Rebelo; João R Pereira; Diogo V Martinho; João P Duarte; Manuel J Coelho-E-Silva; João Valente-Dos-Santos
Journal:  Healthcare (Basel)       Date:  2022-03-22
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.