Literature DB >> 22743123

Intraoperative computer navigation parameters are poor predictors of function 1 year after total knee arthroplasty.

Benjamin J Widmer1, Corey J Scholes, Sébastien Lustig, Leonard Conrad, Sam I Oussedik, David A Parker.   

Abstract

Intraoperative navigation data were collected prospectively for 134 knees undergoing cemented, posterior-stabilized total knee arthroplasty. Partial least squares regression analysis was used to test the association between patient demographics and intraoperative data collected with a computer-assisted navigation system (coronal alignment, ligament balance, range of motion, external tibiofemoral rotation) with 1-year outcomes (36-item Short-Form Health Survey, Oxford Knee Score, range of motion). Age at surgery displayed the largest coefficients of any other predictor. In contrast, navigation coefficients were variable in the strength and direction of their association with the outcome variables. Static knee alignment data obtained intraoperatively have limited capacity to explain the variance in functional outcome at 1 year. Although alignment and component position can be precisely measured intraoperatively, intrinsic patient factors remain dominant in determining the outcome.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22743123     DOI: 10.1016/j.arth.2012.04.018

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  No difference between computer-assisted and conventional total knee arthroplasty: five-year results of a prospective randomised study.

Authors:  Jörg Lützner; Julian Dexel; Stephan Kirschner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-07-14       Impact factor: 4.342

2.  Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation.

Authors:  Corey Scholes; Varun Sahni; Sebastien Lustig; David A Parker; Myles R J Coolican
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-17       Impact factor: 4.342

3.  No differences in clinical outcomes between fixed- and mobile-bearing computer-assisted total knee arthroplasties and no correlations between navigation data and clinical scores.

Authors:  Carlos J Marques; Sandra Daniel; Anusch Sufi-Siavach; Frank Lampe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-15       Impact factor: 4.342

4.  Intraoperative ligament laxity influences functional outcome 1 year after total knee arthroplasty.

Authors:  Eirik Aunan; Thomas Johan Kibsgård; Lien My Diep; Stephan M Röhrl
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-12       Impact factor: 4.342

5.  Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study.

Authors:  Stefan W Kreuzer; Amir Pourmoghaddam; Kevin J Leffers; Clint W Johnson; Marius Dettmer
Journal:  Adv Orthop       Date:  2016-01-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.