Trabecular meshwork length in men and women by histological assessment.

Toshimitsu Kasuga1, Yi-Chun Chen, Michele M Bloomer, Kristin E Hirabayashi, Yoshimune Hiratsuka, Akira Murakami, Shan C Lin.   

Abstract

PURPOSE: To evaluate the length of the trabecular meshwork (TM) from the scleral spur (SS) to Schwalbe's line (SL) and assess the detectability of the SS in histopathology specimens.
METHODS: This study included 158 angle images from 79 cross-sectional slides derived from eyes enucleated for melanoma. The slides were stained with hematoxylin-eosin (HE) or periodic acid schiff (PAS). Two ophthalmologists evaluated the TM length by using the slides stained with HE to assess the interobserver reproducibility. For intraobserver reproducibility, the first observer assessed 79 images in a different session. Also, 30 images that were randomly selected for PAS stain were evaluated to assess the agreement of the measurements between HE and PAS staining. Interclass correlation coefficients (ICC) were calculated to evaluate reproducibility of measurements. The images were also evaluated for detectability of the scleral spurs.
RESULTS: Among the 79 included subjects, 40 were male and 39 were female. The average trabecular meshwork length was 694.9 ± 109.0 µm in the male group and 713.2 ± 106.9 µm in the female group (p = 0.29). Intraobserver and interobserver ICC were 0.89 and 0.62, respectively. ICC for agreement between HE and PAS was 0.89. Among the 158 angles graded, the first observer graded 40 images (25.3%) and the second observer graded 45 (28.5%) as difficult to identify the scleral spur.
CONCLUSIONS: There was no statistically significant difference between the average trabecular meshwork length in men and women. Among the angles evaluated, 25.3-28.5% were graded as difficult to identify the scleral spur.

Entities:  

Mesh:

Year:  2012        PMID: 22742780     DOI: 10.3109/02713683.2012.700757

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  3 in total

1.  Assessment of trabecular meshwork width using swept source optical coherence tomography.

Authors:  Tin A Tun; Mani Baskaran; Ce Zheng; Lisandro M Sakata; Shamira A Perera; Anita S Chan; David S Friedman; Carol Y Cheung; Tin Aung
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-02-23       Impact factor: 3.117

2.  Changes After a Month Following Micropulse Cyclophotocoagulation in Normal Porcine Eyes.

Authors:  So Min Ahn; Mihyun Choi; Seong-Woo Kim; Yong Yeon Kim
Journal:  Transl Vis Sci Technol       Date:  2021-11-01       Impact factor: 3.283

Review 3.  Technological advances in ocular trabecular meshwork in vitro models for glaucoma research.

Authors:  Maria Bikuna-Izagirre; Javier Aldazabal; Leire Extramiana; Javier Moreno-Montañés; Elena Carnero; Jacobo Paredes
Journal:  Biotechnol Bioeng       Date:  2022-07-25       Impact factor: 4.395

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.