Belief is only half the truth--or why screening for heterophilic antibody interference in certain assays makes double sense.

Johan Bjerner1, Nils Bolstad, Armin Piehler.   

Abstract

BACKGROUND: Interference in immunoassays may cause both false-negative and false-positive results. It may be detected using a number of affirmative tests such as reanalysis of certain samples using different assay platforms with known bias, after the addition of blocker antibodies, or assessment of linearity and parallelism following serial doubling dilutions. One should look for interference where it is likely and has high medical impact. Probabilistic Bayesian reasoning is a statistical tool to identify samples where interference is most likely. But when looking for interference where it is likely, do we find it where it has the largest population health consequences?
METHODS: We used information theory to quantify the effect of assay interference by calculating the Shannon information content (using logarithms with base 2). We then obtained lower bounds of the population health consequences of a particular test and combined these expressions to get lower bounds of the population health consequences of interference. RESULTS AND
CONCLUSION: We suggest that assays having a low frequency of true positives should be the primary target of retesting because: (i) assays with a low frequency of true positives exhibit a high likelihood of interference and (ii) the population health consequences of false-positive results are generally higher for assays with a low frequency of true positives. Finally, we give a worked example having a realistic frequency of interference and test costs. In some immunoassays (e.g., tumour markers), adding a blocker to all tests can be a more cost-efficient mean than retesting positive samples.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22740684     DOI: 10.1258/acb.2012.011228

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  2 in total

1.  What makes D-dimer assays suspicious-heterophilic antibodies?

Authors:  Ying Wu; Ying-Xiu Xiao; Teng-Yi Huang; Xian-Yan Zhang; Huan-Bing Zhou; Xue-Xuan Zhang; Ying-E Wu
Journal:  J Clin Lab Anal       Date:  2018-10-15       Impact factor: 2.352

2.  Identification of and solution for false D-dimer results.

Authors:  Xian-Yan Zhang; Xue-Xuan Zhang; Jia-Long Xu; Teng-Yi Huang; Ying Wu; Ye-Ru Yang; Huan-Bin Zhou; Ying-E Wu
Journal:  J Clin Lab Anal       Date:  2020-01-22       Impact factor: 2.352

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.