Literature DB >> 22740272

Medium-term outcome in patients treated with total hip arthroplasty using a modular femoral stem.

Augusto Dagnino1, Guido Grappiolo, Franco M Benazzo, Ian D Learmonth, Lorenzo Spotorno, Nicola Portinaro.   

Abstract

The clinical, radiographic and quality of life results of total hip arthroplasty using the MODULUS cementless modular femoral stem were reviewed. 48 patients who had a total hip arthroplasty using the MODULUS femoral stem were identified. Six had bilateral procedures, resulting in 60 hips with complete clinical and radiographic data. Mean age at implantation was 50 years (range 33 to 82). Mean follow-up was 59 months (range 50 months to 73). There were two early post-operative dislocations (within 2 days). One patient required further surgery to remove heterotopic bone. Mean Harris Hip Score increased from 37 points preoperatively (range, 7 to 66) to 89 points at final review (range, 65 to 100 points). Radiographic evaluation revealed that all implants were stable without evidence of osteolysis but three patients (5%) exhibited heterotopic ossification. Quality of life was evaluated with the SF36. The physical component increased from 29.2 points (range, 18.5 to 46.0) to 51.7 points (range 42.9 to 60.6) and the mental component from 375 points (range, 19.5 to 50.0) to 50 points (range 32,8 to 62.0).

Entities:  

Mesh:

Year:  2012        PMID: 22740272     DOI: 10.5301/HIP.2012.9245

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  4 in total

1.  Cementless modular neck stems: are they a safe option in primary total hip arthroplasty?

Authors:  José M Pelayo-de-Tomás; José L Rodrigo-Pérez; Carlos D Novoa-Parra; Alejandro Lizaur-Utrilla; María Morales-Suárez-Varela; José Antonio Blas-Dobón
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-10-29

2.  Outcomes of neck modularity in total hip arthroplasty: an Italian perspective.

Authors:  R Papalia; A Di Martino; A Caldaria; B Zampogna; V Denaro
Journal:  Musculoskelet Surg       Date:  2019-01-23

Review 3.  How have alternative bearings and modularity affected revision rates in total hip arthroplasty?

Authors:  William M Mihalko; Markus A Wimmer; Carol A Pacione; Michel P Laurent; Robert F Murphy; Carson Rider
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

4.  Comment on: Modular titanium alloy neck failure in total hip replacement.

Authors:  Francesco Benazzo; Loris Perticarini
Journal:  SICOT J       Date:  2017-03-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.