Literature DB >> 22739783

Effect of LVAD outlet graft anastomosis angle on the aortic valve, wall, and flow.

Gizem Inci1, Esra Sorgüven.   

Abstract

Left ventricular assist devices (LVADs), which pump blood from the left ventricle to the aorta are an important therapy option for patients with end-stage cardiovascular diseases. Recent publications show that even with optimized LVADs fatal complications can occur because of the blood deformations around the inflow cannula or through the LVAD outlet graft-aorta anastomosis. This study investigates the effects of the anastomosis geometry on the flow through the aorta, on the pressure and wall shear stress (WSS) distributions on the aortic wall and on the total entropy generation in the anastomosis region. Anastomosis geometry is defined with two angles, one on the coronal plane and the other on the transversal plane. Turbulent flow simulations are performed for each geometry. Results indicate that 3% to 5% of the work given by the LVAD is dissipated because of the viscous losses in the anastomosis region. The entropy generation, as well as the maximum WSS, increases as the inclination angle decreases. Some portion of the blood streaming out of the LVAD conduit flows toward the aortic valve; therefore the reverse-flow region extends up to the aortic valve in some cases, which may be one of the causes of aortic-valve dysfunction. Results of this study provide insight on the importance of the anastomosis geometry on the hemodynamics in the aorta and downstream the aortic valve, stresses on the aortic wall, and viscous losses.

Entities:  

Mesh:

Year:  2012        PMID: 22739783     DOI: 10.1097/MAT.0b013e3182578b6a

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  4 in total

1.  LVAD Outflow Graft Angle and Thrombosis Risk.

Authors:  Alberto Aliseda; Venkat Keshav Chivukula; Patrick Mcgah; Anthony R Prisco; Jennifer A Beckman; Guilherme J M Garcia; Nahush A Mokadam; Claudius Mahr
Journal:  ASAIO J       Date:  2017 Jan/Feb       Impact factor: 2.872

2.  Living Without a Pulse: The Vascular Implications of Continuous-Flow Left Ventricular Assist Devices.

Authors:  Suneet N Purohit; William K Cornwell; Jay D Pal; JoAnn Lindenfeld; Amrut V Ambardekar
Journal:  Circ Heart Fail       Date:  2018-06       Impact factor: 8.790

3.  Outflow graft anastomosis site design could be correlated to aortic valve regurgitation under left ventricular assist device support.

Authors:  Kei Iizuka; Tomohiro Nishinaka; Yuki Ichihara; Takuma Miyamoto; Kenji Yamazaki
Journal:  J Artif Organs       Date:  2017-11-21       Impact factor: 1.731

4.  Optimization of Axial Pump Characteristic Dimensions and Induced Hemolysis for Mechanical Circulatory Support Devices.

Authors:  Theodosios Korakianitis; Mohammad Amin Rezaienia; Gordon Paul; Eldad Avital; Martin Rothman; Sahand Mozafari
Journal:  ASAIO J       Date:  2018 Nov/Dec       Impact factor: 2.872

  4 in total