Literature DB >> 22739217

Direct measurement of proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography in mitral regurgitation: a validation study.

Jose Alberto de Agustín1, Pedro Marcos-Alberca, Covadonga Fernandez-Golfin, Alexandra Gonçalves, Gisela Feltes, Ivan Javier Nuñez-Gil, Carlos Almeria, Jose Luis Rodrigo, Leopoldo Perez de Isla, Carlos Macaya, Jose Zamorano.   

Abstract

BACKGROUND: The two-dimensional (2D) proximal isovelocity surface area (PISA) method has some technical limitations, mainly the geometric assumptions of PISA shape required to calculate effective regurgitant orifice area (EROA). Recently developed single-beat, real-time three-dimensional (3D) color Doppler imaging allows direct measurement of PISA without geometric assumptions. The aim of this study was to validate this novel method in patients with chronic mitral regurgitation (MR).
METHODS: Thirty-three patients were included, 25 (75.7%) with degenerative MR and eight (24.2%) with functional MR. EROA and regurgitant volume were assessed using transthoracic 2D and 3D PISA methods. The quantitative Doppler method and 3D transesophageal echocardiographic planimetry of EROA were used as reference methods.
RESULTS: Both EROA and regurgitant volume assessed using the 3D PISA method had better correlations with the reference methods than conventional 2D PISA. A consistent significant underestimation of EROA and regurgitant volume using 2D PISA was observed, particularly in the assessment of eccentric jets. On the basis of 3D transesophageal echocardiographic planimetry of EROA, 14 patients had severe MR (EROA ≥ 0.4 cm(2)). Of these 14 patients, 42.8% (6 of 14) were underestimated as having nonsevere MR (EROA ≤ 0.4 cm(2)) by the 2D PISA method. In contrast, the 3D PISA method had 92.9% (13 of 14) agreement with 3D transesophageal planimetry in classifying severe MR. Good intraobserver and interobserver agreement for 3D PISA measurements was observed, with intraclass correlation coefficients of 0.96 and 0.92, respectively.
CONCLUSIONS: Direct measurement of PISA without geometric assumptions using single-beat, real-time 3D color Doppler echocardiography is feasible in the clinical setting. MR quantification using this methodology is more accurate than the conventional 2D PISA method.
Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22739217     DOI: 10.1016/j.echo.2012.05.021

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  14 in total

Review 1.  Incremental value of 3-D transesophageal echocardiographic imaging of the mitral valve.

Authors:  Sonia Jain; Joseph F Malouf
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

2.  [Evaluation of mitral regurgitation : How much quantification do we need?]

Authors:  F Kreidel; T Ruf; A Tamm; M Geyer; T Emrich; R S von Bardeleben
Journal:  Herz       Date:  2019-11       Impact factor: 1.443

3.  Usefulness of 3D-PISA as compared to guideline endorsed parameters for mitral regurgitation quantification.

Authors:  Frank P Schmidt; Theresa Gniewosz; Alexander Jabs; Thomas Münzel; Ulrich Hink; Patrizio Lancellotti; Ralph-Stephan von Bardeleben
Journal:  Int J Cardiovasc Imaging       Date:  2014-07-19       Impact factor: 2.357

4.  Artificial intelligence and automation in valvular heart diseases.

Authors:  Qiang Long; Xiaofeng Ye; Qiang Zhao
Journal:  Cardiol J       Date:  2020-06-22       Impact factor: 2.737

Review 5.  [Real-time 3D echocardiography for estimation of severity in valvular heart disease : Impact on current guidelines].

Authors:  T Buck; L Bösche; B Plicht
Journal:  Herz       Date:  2017-05       Impact factor: 1.443

6.  Assessment of mitral valve disease: a review of imaging modalities.

Authors:  Shweta R Motiwala; Francesca N Delling
Journal:  Curr Treat Options Cardiovasc Med       Date:  2015-07

7.  Regurgitation Hemodynamics Alone Cause Mitral Valve Remodeling Characteristic of Clinical Disease States In Vitro.

Authors:  Patrick S Connell; Anam F Azimuddin; Seulgi E Kim; Fernando Ramirez; Matthew S Jackson; Stephen H Little; K Jane Grande-Allen
Journal:  Ann Biomed Eng       Date:  2015-07-30       Impact factor: 3.934

Review 8.  Quantification of mitral valve regurgitation: new solutions provided by 3D echocardiography.

Authors:  Dimitrios Maragiannis; Stephen H Little
Journal:  Curr Cardiol Rep       Date:  2013-08       Impact factor: 2.931

9.  Comparison between 2D and 3D echocardiography for quantitative assessment of mitral regurgitation: Current status.

Authors:  Sudhakar Subramani
Journal:  Ann Card Anaesth       Date:  2022 Apr-Jun

Review 10.  Real-Time Three-Dimensional Echocardiographic Assessment of Severity of Mitral Regurgitation Using Proximal Isovelocity Surface Area and Vena Contracta Area Method. Lessons We Learned and Clinical Implications.

Authors:  Thomas Buck; Björn Plicht
Journal:  Curr Cardiovasc Imaging Rep       Date:  2015
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.