Implementation of a five degree of freedom automated system to determine knee flexibility in vitro.

G S Berns1, M L Hull, H A Patterson.   

Abstract

This article describes an automated system designed to study the complete flexibility functions of the knee in vitro. The system allows five degrees of freedom with flexion angle being fixed, though adjustable from 0 to 45 deg. Loads corresponding to each of the five motions can be applied independently and in any combination. The effect of weight bearing on knee flexibility can also be studied by including axial force as one of the five loads. The relative motions are measured with LVDT's and RVDT's, and the loads are measured with strain gage transducers. The system is digitally controlled with a closed feedback loop, allowing for any combination of programmed loads. A control algorithm on an IBM PC/AT monitors the loads on each axis and continuously adjusts stepping motors to correctly follow programmed loads. The machine coordinate system corresponds to clinically accepted definitions of motion yet retains sequence independence for rotations. Results are presented demonstrating the repeatability of using a functional definition of axis placement to align the leg within the machine. Results are also presented demonstrating the utility of the full flexibility functions of the knee, notably in the determination of significant load interactions between anterior/posterior force and internal/external torque, and varus/valgus torque and internal/external torque.

Entities:  

Mesh:

Year:  1990        PMID: 2273865     DOI: 10.1115/1.2891202

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  3 in total

1.  Anterior opening wedge high tibial osteotomy: the effect of increasing posterior tibial slope on ligament strain.

Authors:  Paul A Martineau; Stephen D Fening; Anthony Miniaci
Journal:  Can J Surg       Date:  2010-08       Impact factor: 2.089

2.  Optimised robot-based system for the exploration of elastic joint properties.

Authors:  M Frey; R Burgkart; F Regenfelder; R Riener
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

3.  Evaluation of three force-position hybrid control methods for a robot-based biological joint-testing system.

Authors:  Hong-Jung Hsieh; Chih-Chung Hu; Tung-Wu Lu; Hsuan-Lun Lu; Mei-Ying Kuo; Chien-Chung Kuo; Horng-Chaung Hsu
Journal:  Biomed Eng Online       Date:  2016-06-07       Impact factor: 2.819

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.