Toward a reference method for leukocyte differential counts in blood: comparison of three flow cytometric candidate methods.

Mikael Roussel1, Bruce H Davis, Thierry Fest, Brent L Wood.   

Abstract

A Complete Blood Count performed by an automated hematology analyzer frequently requires a microscopic slide review. Recently, we and others have proposed combinations of monoclonal antibodies for an extended leukocyte differential by flow cytometry. The aim of this study was to compare the performance of these proposals. Ninety-two samples were analyzed at 2 sites to compare the accuracy of three published methods. Reference methods used were i) cell counter for leukocyte count and ii) microscopic review as defined by CSLI H20-A2 for cell subsets. Comparison of flow cytometers from 2 manufacturers (FC500 and CANTO/LSRII) was performed. Published protocols were adapted to three different models of flow cytometer and each provided similar results in leukocyte subset enumeration, although some discrepancies were noted for each protocol in comparison with the reference method. The conclusion is that each protocol carries advantages and disadvantages and there is no clear "winner". This study supports the fact that flow cytometry is a candidate to become a reference method for the leukocyte differential. None of the tested protocols clearly demonstrated superiority and each had demonstrable deficiencies. Additional work to develop a consensual 8 to 10 color panel is concluded to be necessary for a satisfactory reference method.
Copyright © 2012 International Society for Advancement of Cytometry.

Mesh:

Substances:

Year:  2012        PMID: 22736499     DOI: 10.1002/cyto.a.22092

Source DB:  PubMed          Journal:  Cytometry A        ISSN: 1552-4922            Impact factor:   4.355


  7 in total

1.  Properties of human blood monocytes. I. CD91 expression and log orthogonal light scatter provide a robust method to identify monocytes that is more accurate than CD14 expression.

Authors:  Dorothy Hudig; Kenneth W Hunter; W John Diamond; Doug Redelman
Journal:  Cytometry B Clin Cytom       Date:  2013-10-08       Impact factor: 3.058

2.  Innovation in hematology: morphology and flow cytometry at the crossroads.

Authors:  Marie C Béné; Gina Zini
Journal:  Haematologica       Date:  2016-04       Impact factor: 9.941

3.  Leukocyte-adjusted epigenome-wide association studies of blood from solid tumor patients.

Authors:  Scott M Langevin; E Andres Houseman; William P Accomando; Devin C Koestler; Brock C Christensen; Heather H Nelson; Margaret R Karagas; Carmen J Marsit; John K Wiencke; Karl T Kelsey
Journal:  Epigenetics       Date:  2014-03-26       Impact factor: 4.528

4.  Flow cytometric white blood cell differential using CytoDiff is excellent for counting blasts.

Authors:  Jimin Kahng; Yonggoo Kim; Myungshin Kim; Eun-Jee Oh; Yeon-Joon Park; Kyungja Han
Journal:  Ann Lab Med       Date:  2014-12-08       Impact factor: 3.464

5.  Determination of mononuclear cell count using peripheral smear and flow cytometry in peripheral blood stem cell products: A retrospective study from an Indian cancer center.

Authors:  Aswathi Krishnan; Mohandoss Murugesan; Bindu Therayangalath; Kandathil Joseph Philip; Sangeetha K Nayanar; Chandran K Nair
Journal:  Asian J Transfus Sci       Date:  2021-11-01

6.  In silico-labeled ghost cytometry.

Authors:  Masashi Ugawa; Yoko Kawamura; Keisuke Toda; Kazuki Teranishi; Hikari Morita; Hiroaki Adachi; Ryo Tamoto; Hiroko Nomaru; Keiji Nakagawa; Keiki Sugimoto; Evgeniia Borisova; Yuri An; Yusuke Konishi; Seiichiro Tabata; Soji Morishita; Misa Imai; Tomoiku Takaku; Marito Araki; Norio Komatsu; Yohei Hayashi; Issei Sato; Ryoichi Horisaki; Hiroyuki Noji; Sadao Ota
Journal:  Elife       Date:  2021-12-21       Impact factor: 8.140

7.  High Monocyte Count Associated with Human Cytomegalovirus Replication In Vivo and Glucocorticoid Therapy May Be a Hallmark of Disease.

Authors:  Przemyslaw Zdziarski; Andrzej Gamian
Journal:  Int J Mol Sci       Date:  2022-08-24       Impact factor: 6.208

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.