Literature DB >> 22733949

Mid- to long-term results of revision total knee replacement using press-fit intramedullary stems with cemented femoral and tibial components.

P Manopoulos1, E Havet, O Pearce, J F Lardanchet, P Mertl.   

Abstract

This was a retrospective analysis of the medium- to long-term results of 46 TC3 Sigma revision total knee replacements using long uncemented stems in press-fit mode. Clinical and radiological analysis took place pre-operatively, at two years post-operatively, and at a mean follow-up of 8.5 years (4 to 12). The mean pre-operative International Knee Society (IKS) clinical score was 42 points (0 to 74), improving to 83.7 (52 to 100) by the final follow-up. The mean IKS score for function improved from 34.3 points (0 to 80) to 64.2 (15 to 100) at the final follow-up. At the final follow-up 30 knees (65.2%) had an excellent result, seven (15.2%) a good result, one (2.2%) a medium and eight (17.4%) a poor result. There were two failures, one with anteroposterior instability and one with aseptic loosening. The TC3 revision knee system, when used with press-fit for long intramedullary stems and cemented femoral and tibial components, in both septic and aseptic revisions, results in a satisfactory clinical and radiological outcome, and has a good medium- to long-term survival rate.

Mesh:

Substances:

Year:  2012        PMID: 22733949     DOI: 10.1302/0301-620X.94B7.26943

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  6 in total

1.  Patellofemoral kinematics during deep knee flexion after total knee replacement: a computational simulation.

Authors:  Chang-Hung Huang; Lin-I Hsu; Kun-Jhih Lin; Ting-Kuo Chang; Cheng-Kung Cheng; Yung-Chang Lu; Chen-Sheng Chen; Chun-Hsiung Huang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-03       Impact factor: 4.342

2.  Stress distribution of the patellofemoral joint in the anatomic V-shape and curved dome-shape femoral component: a comparison of resurfaced and unresurfaced patellae.

Authors:  Chang-Hung Huang; Lin-I Hsu; Ting-Kuo Chang; Tai-Yuan Chuang; Shih-Liang Shih; Yung-Chang Lu; Chen-Sheng Chen; Chun-Hsiung Huang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-12-25       Impact factor: 4.342

Review 3.  Fixation of stem in revision of total knee arthroplasty: cemented versus cementless-a meta-analysis.

Authors:  Changyao Wang; Tilman Pfitzner; Philipp von Roth; Hermann O Mayr; Michael Sostheim; Robert Hube
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-12-19       Impact factor: 4.342

4.  Relationship between patient-based outcome score and conventional objective outcome scales in post-operative total knee arthroplasty patients.

Authors:  Eiji Sasaki; Eiichi Tsuda; Yuji Yamamoto; Shugo Meada; Hironori Otsuka; Yasuyuki Ishibashi
Journal:  Int Orthop       Date:  2013-08-24       Impact factor: 3.075

5.  Revision TKA with a condylar constrained prosthesis using metaphyseal and surface cementation: a minimum 6-year follow-up analysis.

Authors:  Pablo Sanz-Ruiz; Manuel Villanueva-Martínez; Jose Antonio Matas-Diez; Javier Vaquero-Martín
Journal:  BMC Musculoskelet Disord       Date:  2015-02-25       Impact factor: 2.362

6.  Revision Total Knee Arthroplasty with Metaphyseal Sleeves without Stem: Short-Term Results.

Authors:  Giacomo Stefani; Valerio Mattiuzzo; Greta Prestini
Journal:  Joints       Date:  2017-10-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.