Literature DB >> 22733252

Refractive surprise following implantation of correct powered intraocular lens--a real surprise!

Kumar Ravi1, Sirisha Senthil, Veerendranath Pesala.   

Abstract

We report a case of a 60-year-old male with unsatisfactory visual outcome following an uneventful phacoemulsification surgery for the left eye at our hospital. The evaluation of his anterior segment revealed a clear cornea, a well-positioned in-the-bag intraocular lens (IOL) and normal posterior segment. His vision in the left eye was 20/160 improving to 20/20 with +6.5 D Sphere. Repeat biometry of the left eye revealed IOL power of 22.0 D, which was same as the power of the IOL implanted during the cataract surgery. The patient underwent IOL explantation and implantation of another foldable IOL of 22.0 D. On follow-up he had an uncorrected visual acuity of 20/20. On evaluation with the Scheiner optical system, the explanted lens was found to have power of +13.92 D. This case highlights the rare possibility of postoperative refractory surprise due to incorrect labelling of the IOL by the manufacturer.

Entities:  

Mesh:

Year:  2012        PMID: 22733252     DOI: 10.1007/s10792-012-9598-1

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  5 in total

1.  How can this happen?

Authors:  Randy Burks
Journal:  Ophthalmology       Date:  2005-11       Impact factor: 12.079

2.  Incorrect IOL selection.

Authors:  Joel Porter
Journal:  Ophthalmology       Date:  2006-05       Impact factor: 12.079

Review 3.  Intraocular lens complications requiring removal or exchange.

Authors:  A N Carlson; W C Stewart; P C Tso
Journal:  Surv Ophthalmol       Date:  1998 Mar-Apr       Impact factor: 6.048

4.  Wrong intraocular lens implant; learning from reported patient safety incidents.

Authors:  S P Kelly; A Jalil
Journal:  Eye (Lond)       Date:  2011-02-25       Impact factor: 3.775

5.  Changing indications for and improving outcomes of intraocular lens exchange.

Authors:  George J C Jin; Alan S Crandall; Jason J Jones
Journal:  Am J Ophthalmol       Date:  2005-10       Impact factor: 5.258

  5 in total
  3 in total

Review 1.  "Numbers sometimes lie"- refractive surprise following IOL mislabeling by the manufacturer.

Authors:  Marija Antičić; Navid Ardjomand; Stephanie Sarny; Jakob Schweighofer; Yosuf El-Shabrawi
Journal:  Eye (Lond)       Date:  2019-02-13       Impact factor: 3.775

2.  Intraocular Lens Fragmentation Using Femtosecond Laser: An In Vitro Study.

Authors:  Chandra Bala; Jeffrey Shi; Kerrie Meades
Journal:  Transl Vis Sci Technol       Date:  2015-06-11       Impact factor: 3.283

3.  In Vivo Intraocular Lens Thickness Measurement and Power Estimation Using Optical Coherence Tomography.

Authors:  Ehsan Barzanouni; Diba Idani; Farideh Sharifipour
Journal:  J Ophthalmic Vis Res       Date:  2022-08-15
  3 in total