Literature DB >> 22730760

[Intracoronary Stenting and Angiographic Results Strut Thickness Effect on Restenosis Outcome (ISAR-STEREO) Trial].

Adnan Kastrati, Julinda Mehilli, Josef Dirschinger, Franz Dotzer, Helmut Schuhlen, Franz-Josef Neumann, Martin Fleckenstein, Conrad Pfafferott, Melchior Seyfarth, Albert Schomig.   

Abstract

BACKGROUND: Increased thrombogenicity and smooth muscle cell proliferative response induced by the metal struts compromise the advantages of coronary stenting. The objective of this randomized, multicenter study was to ascertain whether a reduced strut thickness of a stent is associated with improved follow-up angiographic and clinical results. METHODS AND
RESULTS: The study covered 651 patients with stenosis in the native coronary arteries > 2.8 mm in diameter. They were randomly assigned to receive 1 of 2 commercially available stents of comparable design but different thickness: 326 patients to the thin-strut stent (strut thickness of 50 microm) and 325 patients to the thicker-strut stent (strut thickness of 140 microm). The primary end point was the angiographic restenosis (> or = 50% diameter luminal stenosis at follow-up angiography). The secondary end points were the incidence of reinterventions due to restenosis-induced ischemia and the total rate of death and myocardial infarctions at 1 year (a combined end point). The incidence of angiographic restenosis was 15.0% in the thin-strut group and 25.8% in the thick-strut group (relative risk, 0.58; 95% CI, 0.39 to 0.87; p = 0.003). Clinical restenosis was also significantly reduced. Reinterventions were made in 8.6% of the thin-strut patients and in 13.8% of the thick-strut patients (relative risk, 0.62; 95% CI, 0.39 to 0.99; p = 0.03). No difference was observed in the combined 1-year rate of death and myocardial infarction.
CONCLUSIONS: The use of a thin-strut device is associated with a significant reduction of angiographic and clinical restenosis after coronary artery stenting. These findings may have relevant implications for the currently most widely used percutaneous coronary intervention.

Entities:  

Mesh:

Year:  2012        PMID: 22730760

Source DB:  PubMed          Journal:  Vestn Rentgenol Radiol        ISSN: 0042-4676


  6 in total

1.  Dual antiplatelet therapy duration after the placement of a drug-eluting stent: what are the data?

Authors:  Jad Raffoul; Andrew J P Klein
Journal:  Curr Treat Options Cardiovasc Med       Date:  2015-03

2.  Clinical Outcomes of World's Thinnest (50 μmr) Strut Biodegradable Polymer Coated Everolimus-Eluting Coronary Stent System in Real-World Patients.

Authors:  Suresh V Patted; Anmol Suresh Patted; Prakash Kumar Turiya; Ashok S Thakkar
Journal:  Cardiol Res       Date:  2018-12-07

3.  Twelve-month comparative analysis of clinical outcomes using biodegradable polymer-coated everolimus-eluting stents versus durable polymer-coated everolimus-eluting stents in all-comer patients.

Authors:  Atul Abhyankar; Manjinder Singh Sandhu; Raghava Sarma Polavarapu
Journal:  Indian Heart J       Date:  2019-05-03

4.  Safety and Clinical Performance of Biodegradable Polymer-Coated Ultra-Thin Everolimus-Eluting Stents in "Real-World" Patients: A Multicenter Registry (PERFORM-EVER).

Authors:  Sridhar Kasturi; Srinivas Polasa; Mohammad Ali Sowdagar; Praveen Kumar; Thejanandan Reddy; Chaitanya Nichenamatla; Shailender Singh; Vijaykumar Reddy
Journal:  Anatol J Cardiol       Date:  2022-08       Impact factor: 1.475

5.  Mechanical and Histopathological Comparison between Commercialized and Newly Designed Coronary Bare Metal Stents in a Porcine Coronary Restenosis Model.

Authors:  Kyung Seob Lim; In Ho Bae; Jung Ha Kim; Dae Sung Park; Jong Min Kim; Jung Hyun Kim; Doo Sun Sim; Young Joon Hong; Myung Ho Jeong
Journal:  Chonnam Med J       Date:  2013-04-25

6.  Elastic stent recoil in coronary total occlusions: Comparison of durable-polymer zotarolimus eluting stent and ultrathin strut bioabsorbable-polymer sirolimus eluting stent.

Authors:  Riccardo Improta; Paola Scarparo; Jeroen Wilschut; Quinten Wolff; Joost Daemen; Wijnand K Den Dekker; Felix Zijlstra; Nicolas M Van Mieghem; Roberto Diletti
Journal:  Catheter Cardiovasc Interv       Date:  2021-05-07       Impact factor: 2.585

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.