Literature DB >> 22730218

Inner-volume imaging in vivo using three-dimensional parallel spatially selective excitation.

Johannes T Schneider1, Raffi Kalayciyan, Martin Haas, Sarah R Herrmann, Wolfgang Ruhm, Jürgen Hennig, Peter Ullmann.   

Abstract

This work describes the first experimental realization of three-dimensional spatially selective excitation using parallel transmission in vivo. For the design of three-dimensional parallel excitation pulses with short durations and high excitation accuracy, the choice of a suitable transmit k-space trajectory is crucial. For this reason, the characteristics of a stack-of-spirals trajectory and of a concentric-shells trajectory were examined in an initial simulation study. It showed that, especially when undersampling the trajectories in combination with parallel transmission, experimental parameters such as transmit-coil geometry and off-resonance conditions have an essential impact on the suitability of the selected trajectory and undersampling scheme. Both trajectories were applied in MR inner-volume imaging experiments which demonstrate that acceptably short and robust three-dimensional selective pulses can be achieved if the trajectory is temporally optimized and its actual path is measured and considered during pulse calculation. Pulse durations as short as 3.2 ms were realized and such pulses were appropriate to accurately excite arbitrarily shaped volumes in a corn cob and in a rat in vivo. Reduced field-of-view imaging of these selectively excited targets allowed high spatial resolution and significantly reduced measurement times and furthermore demonstrates the feasibility of three-dimensional parallel excitation in realistic MRI applications in vivo.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22730218     DOI: 10.1002/mrm.24381

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  Localized diffusion magnetic resonance micro-imaging of the live mouse brain.

Authors:  Dan Wu; Dominik Reisinger; Jiadi Xu; S Ali Fatemi; Peter C M van Zijl; Susumu Mori; Jiangyang Zhang
Journal:  Neuroimage       Date:  2014-01-17       Impact factor: 6.556

2.  Joint Design of Excitation k-Space Trajectory and RF Pulse for Small-Tip 3D Tailored Excitation in MRI.

Authors:  Sun Hao; Jeffrey A Fessler; Douglas C Noll; Jon-Fredrik Nielsen
Journal:  IEEE Trans Med Imaging       Date:  2015-09-15       Impact factor: 10.048

Review 3.  Parallel Transmission for Ultrahigh Field MRI.

Authors:  Cem M Deniz
Journal:  Top Magn Reson Imaging       Date:  2019-06

4.  Local SAR, global SAR, and power-constrained large-flip-angle pulses with optimal control and virtual observation points.

Authors:  Mads S Vinding; Bastien Guérin; Thomas Vosegaard; Niels Chr Nielsen
Journal:  Magn Reson Med       Date:  2015-12-30       Impact factor: 4.668

5.  In utero localized diffusion MRI of the embryonic mouse brain microstructure and injury.

Authors:  Dan Wu; Jun Lei; Jason M Rosenzweig; Irina Burd; Jiangyang Zhang
Journal:  J Magn Reson Imaging       Date:  2014-12-24       Impact factor: 4.813

6.  Accelerated imaging with segmented 2D pulses using parallel imaging and virtual coils.

Authors:  Michael Mullen; Alexander Gutierrez; Naoharu Kobayashi; Jarvis Haupt; Michael Garwood
Journal:  J Magn Reson       Date:  2019-07-04       Impact factor: 2.229

7.  Reduced field of view imaging using a static second-order gradient for functional MRI applications.

Authors:  Haisam Islam; Gary H Glover
Journal:  Magn Reson Med       Date:  2015-03-25       Impact factor: 4.668

8.  A GRAPPA algorithm for arbitrary 2D/3D non-Cartesian sampling trajectories with rapid calibration.

Authors:  Tianrui Luo; Douglas C Noll; Jeffrey A Fessler; Jon-Fredrik Nielsen
Journal:  Magn Reson Med       Date:  2019-05-03       Impact factor: 4.668

9.  Fast three-dimensional inner volume excitations using parallel transmission and optimized k-space trajectories.

Authors:  Mathias Davids; Lothar R Schad; Lawrence L Wald; Bastien Guérin
Journal:  Magn Reson Med       Date:  2015-11-03       Impact factor: 4.668

10.  Rapid inner-volume imaging in the steady-state with 3D selective excitation and small-tip fast recovery imaging.

Authors:  Hao Sun; Jeffrey A Fessler; Douglas C Noll; Jon-Fredrik Nielsen
Journal:  Magn Reson Med       Date:  2015-10-28       Impact factor: 4.668

View more