A sensor for needle puncture force measurement during interventional radiological procedures.

J Zhai1, K Karuppasamy, R Zvavanjanja, M Fisher, A C Fisher, D Gould, T How.   

Abstract

Computer-based simulation for interventional radiology training has attracted increasing attention in recent years because of its potential to train remotely from patients and to provide objective assessment of proficiency. Yet developing a high fidelity simulator with realistic tactile feedback requires accurate knowledge of forces exerted on medical devices during interventional radiology procedures. This paper presents the development and validation of a force sensor for the measurement of axial forces generated during needle, and combined cannula/trocar, puncture procedures in patients. In order to assess the performance of this sensor, in vitro measurements were obtained using needle penetration of porcine liver, kidney and muscle. The results were compared with forces measured by means of a tensile tester. Calibration results showed that the force sensor has high sensitivity and linearity. Comparison of the force profiles obtained from the sensor and the tensile tester shows that good agreement was achieved in the in vitro studies for all the tissues tested. Preliminary clinical force measurements during arterial puncture and liver biopsy procedures have been performed in patients. An example of force recording for each procedure type is presented. Crown
Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22728156     DOI: 10.1016/j.medengphy.2012.05.012

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  3 in total

Review 1.  Force Modeling, Identification, and Feedback Control of Robot-Assisted Needle Insertion: A Survey of the Literature.

Authors:  Chongjun Yang; Yu Xie; Shuang Liu; Dong Sun
Journal:  Sensors (Basel)       Date:  2018-02-12       Impact factor: 3.576

2.  A Micro-Force Sensor with Beam-Membrane Structure for Measurement of Friction Torque in Rotating MEMS Machines.

Authors:  Huan Liu; Zhongliang Yu; Yan Liu; Xudong Fang
Journal:  Micromachines (Basel)       Date:  2017-10-12       Impact factor: 2.891

3.  A micro-force sensor with slotted-quad-beam structure for measuring the friction in MEMS bearings.

Authors:  Huan Liu; Shuming Yang; Yulong Zhao; Zhuangde Jiang; Yan Liu; Bian Tian
Journal:  Sensors (Basel)       Date:  2013-09-30       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.