Literature DB >> 22727735

Kinematic and electromyographic analyses of normal and device-assisted sit-to-stand transfers.

Judith M Burnfield1, Yu Shu, Thad W Buster, Adam P Taylor, Michaela M McBride, Megan E Krause.   

Abstract

Mechanical sit-to-stand devices assist patient transfers and help protect against work-related injuries in rehabilitation environments. However, observational differences between patient's movements within devices compared to normal sit-to-stand transfers deter clinician use. This study compared kinematics and muscle demands during sit-to-stand transfers with no device (ND), and device-assisted during which participants exerted no effort (DA-NE) and best effort (DA-BE). Coefficient of multiple correlations (CMCs) compared kinematic profiles during each device-assisted condition to ND. Compared to DA-NE, CMCs were higher during DA-BE at the hip, knee, and ankle. However, DA-BE values were lower than DA-NE at the trunk and pelvis due to the device's mechanical constraints. In general, all joints' final DA-NE postures were more flexed than other conditions. Electromyographic was significantly lower during DA-NE compared to ND for all muscles except lateral hamstring, and during DA-BE compared to ND for gluteus maximus, gastrocnemius, and soleus. Verbal encouragement (DA-BE) significantly increased medial hamstring, vastus lateralis, gastrocnemius, soleus and tibialis anterior activation compared to DA-NE. In conclusion, device-assisted sit-to-stand movements differed from normal sit-to-stand patterns. Verbally encouraging best effort during device-assisted transfers elevated select lower extremity muscle activation and led to greater similarity in hip, knee and ankle movement profiles. However, trunk and pelvis profiles declined.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22727735     DOI: 10.1016/j.gaitpost.2012.05.002

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  7 in total

1.  The influence of knee extensor fatigue on lower extremity muscle activity during chair rise in young and older adults.

Authors:  Megan A Bryanton; Martin Bilodeau
Journal:  Eur J Appl Physiol       Date:  2018-10-13       Impact factor: 3.078

2.  Effects of a safe patient handling and mobility program on patient self-care outcomes.

Authors:  Amy R Darragh; Mariya Shiyko; Heather Margulis; Marc Campo
Journal:  Am J Occup Ther       Date:  2014 Sep-Oct

3.  Kinematic analysis of the human body during sit-to-stand in healthy young adults.

Authors:  Jin Li; Qiang Xue; Shuo Yang; Xiaolong Han; Shouwei Zhang; Min Li; Jingchen Guo
Journal:  Medicine (Baltimore)       Date:  2021-06-04       Impact factor: 1.817

4.  Effect of hip joint angle at seat-off on hip joint contact force during sit-to-stand movement: a computer simulation study.

Authors:  Takuma Inai; Tomoya Takabayashi; Mutsuaki Edama; Masayoshi Kubo
Journal:  Biomed Eng Online       Date:  2018-11-29       Impact factor: 2.819

5.  Fatigue Detection during Sit-To-Stand Test Based on Surface Electromyography and Acceleration: A Case Study.

Authors:  Cristina Roldán Jiménez; Paul Bennett; Andrés Ortiz García; Antonio I Cuesta Vargas
Journal:  Sensors (Basel)       Date:  2019-09-27       Impact factor: 3.576

6.  Muscular Activity and Fatigue in Lower-Limb and Trunk Muscles during Different Sit-To-Stand Tests.

Authors:  Cristina Roldán-Jiménez; Paul Bennett; Antonio I Cuesta-Vargas
Journal:  PLoS One       Date:  2015-10-27       Impact factor: 3.240

7.  Comparison of Healthcare Workers Transferring Patients Using Either Conventional Or Robotic Wheelchairs: Kinematic, Electromyographic, and Electrocardiographic Analyses.

Authors:  Hiromi Matsumoto; Masaru Ueki; Kazutake Uehara; Hisashi Noma; Nobuko Nozawa; Mari Osaki; Hiroshi Hagino
Journal:  J Healthc Eng       Date:  2016       Impact factor: 2.682

  7 in total