Literature DB >> 22727473

Ultrasound-CT fusion compared with MR-CT fusion for postimplant dosimetry in permanent prostate brachytherapy.

David Bowes1, Juanita M Crook, Cynthia Araujo, Deidre Batchelar.   

Abstract

PURPOSE: Postplan evaluation is essential for quality assurance in prostate brachytherapy. MRI has demonstrated greater interobserver consistency in prostate contouring compared with CT. Although a valuable tool in postimplant assessment, MRI is costly and not always available. Our purpose is to compare dosimetry obtained using fusion of postimplant CT with preimplant transrectal ultrasound (TRUS) vs. CT-MR fusion. METHODS AND MATERIALS: Twenty patients receiving permanent (125)I seed prostate brachytherapy underwent preimplant TRUS with urethrography, 1-month CT with a Foley catheter, and 1-month MRI. No patient received androgen deprivation therapy or external beam radiotherapy. The prescription dose of (125)I implant monotherapy was 144Gy. The preimplant TRUS and postimplant CT images were fused based on urethral position, and the CT-TRUS images were subsequently fused to the MRI using a seed-to-seed match. Dosimetric parameters for the ultrasound- and MR-derived prostate were compared.
RESULTS: The mean absolute difference between dosimetry from MRI or CT-TRUS fusion for D(90) was 3.2% and in V(100) was 1.2%. Only 1 patient had a difference in MR- and ultrasound-derived D(90) of more than 10% (11.4%) and only 1 had a difference in V(100) of more than 5%.
CONCLUSIONS: Fusion of preimplant TRUS with 1-month postimplant CT appears to lead to acceptable agreement with MR-based dosimetric parameters in postplan evaluation. TRUS-based volumes may be a reasonable alternative to MRI in settings where MRI is not available.
Copyright © 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22727473     DOI: 10.1016/j.brachy.2012.03.007

Source DB:  PubMed          Journal:  Brachytherapy        ISSN: 1538-4721            Impact factor:   2.362


  4 in total

1.  Evaluation of transrectal ultrasound-based dosimetry for brachytherapy of prostate cancer: a single-center experience.

Authors:  Changzhao Yang; Zhengtong Lv; Lingxiao Chen; Jie Wang; Xiheng Hu; Harripersaud Chand; Xi Sun; Guyu Tang; Congyi Tang; Huichuan Jiang; Yuan Li
Journal:  J Contemp Brachytherapy       Date:  2020-08-21

2.  Deformable registration of PET/CT and ultrasound for disease-targeted focal prostate brachytherapy.

Authors:  Sharmin Sultana; Daniel Y Song; Junghoon Lee
Journal:  J Med Imaging (Bellingham)       Date:  2019-09-12

3.  Fusion of Intraoperative Transrectal Ultrasound Images with Post-implant Computed Tomography and Magnetic Resonance Imaging.

Authors:  Guila Delouya; Jean-Francois Carrier; Renée Xavier-Larouche; Yannick Hervieux; Dominic Béliveau-Nadeau; David Donath; Daniel Taussky
Journal:  Cureus       Date:  2018-03-29

4.  Dosimetric outcomes of preoperative treatment planning with intraoperative optimization using stranded seeds in prostate brachytherapy.

Authors:  Jason Joon Bock Lee; Eungman Lee; Won Hoon Choi; Jihun Kim; Kyung Hwan Chang; Dong Wook Kim; Han Back Shin; Tae Hyung Kim; Hwa Kyung Byun; Jaeho Cho
Journal:  PLoS One       Date:  2022-03-30       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.