Literature DB >> 22724585

In vivo near-infrared autofluorescence imaging of pigmented skin lesions: methods, technical improvements and preliminary clinical results.

Shuang Wang1, Jianhua Zhao, Harvey Lui, Qingli He, Haishan Zeng.   

Abstract

BACKGROUND/PURPOSES: Fluorescence emission from in vivo cutaneous melanin was recently detected under near-infrared (NIR) excitation by our group. We then built a prototype NIR autofluorescence imaging system to observe and characterize the melanin distribution in human skin. In this article, we reported a new setup of NIR fluorescence imaging system and calibration methods to optimize the system for better clinical feasibility and clearer image.
METHODS: The imaging system was designed to perform both fluorescence and reflectance imaging with a 785-nm fiber-coupled laser source. The illumination light was purified by a 785-nm bandpass filter for fluorescence excitation; while the spontaneous components were selected by a longpass filter for NIR reflectance imaging. A hand-controlled filter wheel was used to switch these two filters for different imaging modes. A dichroic filter was used to guide the illuminating light onto the skin surface for excitation. Reflectance and fluorescence signals were collected sequentially by a NIR optimized CCD camera. The captured images were calibrated by the reflectance images of a standard reflectance disk for non-uniform illuminations and light collection efficiencies.
RESULTS: The clinical results demonstrated that NIR fluorescence intensities and distribution patterns vary among lesion types. It was also confirmed that pigmented skin lesions emitted higher NIR fluorescence than the surrounding normal skin due to the presentation of higher concentrations of cutaneous melanin within the lesions.
CONCLUSION: NIR autofluorescence imaging system could be utilized as a powerful tool for visualizing melanin distribution in pigmented skin lesions and as a potential method for aiding melanoma detection.
© 2012 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22724585     DOI: 10.1111/j.1600-0846.2012.00632.x

Source DB:  PubMed          Journal:  Skin Res Technol        ISSN: 0909-752X            Impact factor:   2.365


  5 in total

1.  Near infrared fluorescent imaging of brain tumor with IR780 dye incorporated phospholipid nanoparticles.

Authors:  Shihong Li; Jennifer Johnson; Anderson Peck; Qian Xie
Journal:  J Transl Med       Date:  2017-01-23       Impact factor: 5.531

2.  Spectroscopic and Imaging Characteristics of Pigmented Non-Melanoma Skin Cancer and Melanoma in Patients with Skin Phototypes III and IV.

Authors:  Stefanie Arroyo-Camarena; Judith Domínguez-Cherit; Lorena Lammoglia-Ordiales; Diego A Fabila-Bustos; Abraham Escobar-Pio; Suren Stolik; Alma Valor-Reed; José de la Rosa-Vázquez
Journal:  Oncol Ther       Date:  2016-12-12

Review 3.  Recent Advances and the Potential for Clinical Use of Autofluorescence Detection of Extra-Ophthalmic Tissues.

Authors:  Jonas Wizenty; Teresa Schumann; Donna Theil; Martin Stockmann; Johann Pratschke; Frank Tacke; Felix Aigner; Tilo Wuensch
Journal:  Molecules       Date:  2020-04-30       Impact factor: 4.411

Review 4.  Skin cancer detection using non-invasive techniques.

Authors:  Vigneswaran Narayanamurthy; P Padmapriya; A Noorasafrin; B Pooja; K Hema; Al'aina Yuhainis Firus Khan; K Nithyakalyani; Fahmi Samsuri
Journal:  RSC Adv       Date:  2018-08-06       Impact factor: 4.036

5.  Melanin distribution from the dermal-epidermal junction to the stratum corneum: non-invasive in vivo assessment by fluorescence and Raman microspectroscopy.

Authors:  B P Yakimov; E A Shirshin; J Schleusener; A S Allenova; V V Fadeev; M E Darvin
Journal:  Sci Rep       Date:  2020-09-01       Impact factor: 4.379

  5 in total