INTRODUCTION: High frequency ultrasonography (HFUS) is a non-invasive, low risk method which can provide real-time visual information regarding different processes in cutaneous tissue. The goal of this study is to compare the accuracy of HFUS in determining depth and width of basal cell carcinoma (BCC) lesions compared with histopathology as a reference standard. METHODS: The depth and width of 56 primary BCCs in various locations were measured in vivo using the ultrasound system device Digital Taberna Promedica (Luneburg, FRG DUB 20 Ultrasound Scanner), with a 50-MHz hand-held transducer and compared with the depth and width reported in histopathologic examination of these lesions after complete excision. The intraclass correlation coefficient (ICC) was calculated using a one-way ANOVA table to compare measured dimensions for the same tumors with the two diagnostic methods. RESULTS: The mean depth of tumor in HFUS (1353.68 ± 656.456 microns) was lower than the amount measured by the dermatopathologist (1560.71 ± 1044.323 microns). However, the difference was not statistically significant (P > 0.05). The means of largest diameter of tumors in HFUS and pathology were 5996.77 ± 2271.783 and 3891.07 ± 1995.452 microns, respectively (P < 0.001). There was a low correlation in diameter (r = 0.27, P < 0.05) and a moderate correlation in depth (r = 0.45, P < 0.001) of BCCs between these two methods. CONCLUSION: HFUS may be a useful method to assess the dimensions of BCC prior to surgery.
INTRODUCTION: High frequency ultrasonography (HFUS) is a non-invasive, low risk method which can provide real-time visual information regarding different processes in cutaneous tissue. The goal of this study is to compare the accuracy of HFUS in determining depth and width of basal cell carcinoma (BCC) lesions compared with histopathology as a reference standard. METHODS: The depth and width of 56 primary BCCs in various locations were measured in vivo using the ultrasound system device Digital Taberna Promedica (Luneburg, FRG DUB 20 Ultrasound Scanner), with a 50-MHz hand-held transducer and compared with the depth and width reported in histopathologic examination of these lesions after complete excision. The intraclass correlation coefficient (ICC) was calculated using a one-way ANOVA table to compare measured dimensions for the same tumors with the two diagnostic methods. RESULTS: The mean depth of tumor in HFUS (1353.68 ± 656.456 microns) was lower than the amount measured by the dermatopathologist (1560.71 ± 1044.323 microns). However, the difference was not statistically significant (P > 0.05). The means of largest diameter of tumors in HFUS and pathology were 5996.77 ± 2271.783 and 3891.07 ± 1995.452 microns, respectively (P < 0.001). There was a low correlation in diameter (r = 0.27, P < 0.05) and a moderate correlation in depth (r = 0.45, P < 0.001) of BCCs between these two methods. CONCLUSION: HFUS may be a useful method to assess the dimensions of BCC prior to surgery.
Authors: Samantha L Schneider; Indermeet Kohli; Iltefat H Hamzavi; M Laurin Council; Anthony M Rossi; David M Ozog Journal: J Am Acad Dermatol Date: 2018-12-04 Impact factor: 11.527
Authors: Olga Pons-Llanas; Rosa Ballester-Sánchez; Francisco Javier Celada-Álvarez; Cristian Candela-Juan; Teresa García-Martínez; Margarita Llavador-Ros; Rafael Botella-Estrada; Christopher A Barker; Antonio Ballesta; Alejandro Tormo-Micó; Silvia Rodríguez; Jose Perez-Calatayud Journal: J Contemp Brachytherapy Date: 2014-12-31
Authors: Rosa Ballester-Sánchez; Olga Pons-Llanas; Cristian Candela-Juan; Francisco Javier Celada-Alvarez; Blanca de Unamuno-Bustos; Margarita Llavador-Ros; Antonio Ballesta-Cuñat; Christopher A Barker; Alejandro Tormo-Mico; Rafael Botella-Estrada; Jose Perez-Calatayud Journal: J Contemp Brachytherapy Date: 2015-06-09
Authors: Rosa Ballester-Sánchez; Olga Pons-Llanas; Margarita Llavador-Ros; Rafael Botella-Estrada; Antonio Ballester-Cuñat; Alejandro Tormo-Micó; Francisco Javier Celadá-Álvarez; Silvia Rodríguez-Villalba; Manuel Santos-Ortega; Facundo Ballester-Pallarés; Jose Perez-Calatayud Journal: J Contemp Brachytherapy Date: 2014-12-31
Authors: Elisa de Oliveira Barcaui; Antonio Carlos Pires Carvalho; Paulo Marcos N Valiante; Carlos Baptista Barcaui Journal: An Bras Dermatol Date: 2014 Sep-Oct Impact factor: 1.896
Authors: Elisa de Oliveira Barcaui; Antonio Carlos Pires Carvalho; Flavia Paiva Proença Lobo Lopes; Juan Piñeiro-Maceira; Carlos Baptista Barcaui Journal: An Bras Dermatol Date: 2016 May-Jun Impact factor: 1.896
Authors: Hyeon Jo Kim; Seong Joo Lee; Ju Ho Lee; Se Ho Shin; Huiying Xu; Ik Yang; Jae Hyun Kim; Seong Hwan Kim; In Suck Suh Journal: Medicine (Baltimore) Date: 2020-12-18 Impact factor: 1.817