Effect of prior probability quality on biased time-delay estimation.

Brett C Byram1, Gregg E Trahey, Mark L Palmeri.   

Abstract

When properly constructed, biased estimators are known to produce lower mean-square errors than unbiased estimators. A biased estimator for the problem of ultrasound time-delay estimation was recently proposed. The proposed estimator incorporates knowledge of adjacent displacement estimates into the final estimate of a displacement. This is accomplished by using adjacent estimates to create a prior probability on the current estimate. Theory and simulations are used to investigate how the prior probability impacts the final estimate. The results show that with estimation quality on the order of the Cramer-Rao lower bound at adjacent locations, the local estimate in question should generally exceed the Cramer-Rao lower-bound limitations on performance of an unbiased estimator. The results as a whole provide additional confidence for the proposed estimator.

Entities:  

Mesh:

Year:  2012        PMID: 22724313      PMCID: PMC3493255          DOI: 10.1177/016173461203400201

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  6 in total

1.  Ultrasound elastography based on multiscale estimations of regularized displacement fields.

Authors:  Claire Pellot-Barakat; Frédérique Frouin; Michael F Insana; Alain Herment
Journal:  IEEE Trans Med Imaging       Date:  2004-02       Impact factor: 10.048

2.  Rapid tracking of small displacements with ultrasound.

Authors:  Gianmarco F Pinton; Jeremy J Dahl; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-06       Impact factor: 2.725

3.  Ultrasonic tracking of acoustic radiation force-induced displacements in homogeneous media.

Authors:  Mark L Palmeri; Stephen A McAleavey; Gregg E Trahey; Kathryn R Nightingale
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-07       Impact factor: 2.725

4.  Motion estimation in ultrasound images using time domain cross correlation with prior estimates.

Authors:  Reza Zahiri-Azar; Septimiu E Salcudean
Journal:  IEEE Trans Biomed Eng       Date:  2006-10       Impact factor: 4.538

5.  2-D companding for noise reduction in strain imaging.

Authors:  P Chaturvedi; M F Insana; T J Hall
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

6.  A new elastographic method for estimation and imaging of lateral displacements, lateral strains, corrected axial strains and Poisson's ratios in tissues.

Authors:  E Konofagou; J Ophir
Journal:  Ultrasound Med Biol       Date:  1998-10       Impact factor: 2.998

  6 in total
  1 in total

1.  The feasibility of myocardial infarct visualization using atrial kick induced strain (AKIS) contrast.

Authors:  Brett Byram; Han Kim; Lowie Van Assche; Patrick D Wolf; Gregg E Trahey
Journal:  Ultrasound Med Biol       Date:  2014-03-07       Impact factor: 2.998

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.