Literature DB >> 22723042

Interdisciplinary consensus recommendations for the use of vacuum-assisted breast biopsy under sonographic guidance: first update 2012.

M Hahn1, U Krainick-Strobel, T Toellner, J Gissler, S Kluge, E Krapfl, U Peisker, V Duda, F Degenhardt, H P Sinn, D Wallwiener, I V Gruber.   

Abstract

PURPOSE: The vacuum biopsy of the breast under sonographic guidance (VB) was introduced in Germany in the year 2000 and the first consensus recommendations were published by Krainick-Strobel et al. in 2005. Since then, many clinical studies on this technique have been published. The purpose of this publication is to update the consensus recommendations from 2005 regarding the latest literature.
MATERIALS AND METHODS: The consensus statements were the result of two preliminary meetings after the review of the latest literature by members of the Minimally Invasive Breast Intervention Study Group from the German Society of Senology. The final consensus text was review by all members of the working group. The statements listed under results obtained complete acceptance (consensus 100 %).
RESULTS: The consensus recommendations describe the indications, investigator qualifications, technical requirements, documentation, quality assurance and follow-up intervals regarding the latest literature.
CONCLUSION: The VB is a safe method for extracting breast tissue for histological workup. The technique allows the resection of breast tissue up to 8 cm3. Besides the diagnostic indications, the method qualifies for a therapeutic resection of symptomatic benign lesions (e. g. fibroadenomas). The technique should be used in specialized breast centers working in a multidisciplinary setup. This paper is an expert's recommendation for the use of VB under sonographic guidance. It is not formulated as a nationwide guideline. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2012        PMID: 22723042     DOI: 10.1055/s-0032-1312831

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  14 in total

1.  Minimally Invasive Breast Fibroadenoma Excision Using an Ultrasound-Guided Vacuum-Assisted Biopsy Device.

Authors:  Thomas Papathemelis; Stefanie Heim; Michael P Lux; Ines Erhardt; Anton Scharl; Sophia Scharl
Journal:  Geburtshilfe Frauenheilkd       Date:  2017-02       Impact factor: 2.915

Review 2.  The Evolving Role of Vacuum Assisted Biopsy of the Breast: A Progression from Fine-Needle Aspiration Biopsy.

Authors:  Ian C Bennett; Apoorva Saboo
Journal:  World J Surg       Date:  2019-04       Impact factor: 3.352

Review 3.  Differentiating vacuum-assisted breast biopsy from core needle biopsy: Is it necessary?

Authors:  Satoko Nakano; Yoshimi Imawari; Akemi Mibu; Masahiko Otsuka; Toshinori Oinuma
Journal:  Br J Radiol       Date:  2018-07-20       Impact factor: 3.039

4.  Ultrasound Guided Therapeutic Excisional Vacuum Assisted Biopsy in Breast Fibroadenomas.

Authors:  Onur Buğdaycı; Handan Kaya; Erkin Arıbal
Journal:  J Breast Health       Date:  2017-04-01

5.  Both a biopsy method and a therapeutic procedure in BI-RADS 4A and 4B lesions: Ultrasound-guided vacuum-assisted breast biopsy.

Authors:  Funda Dinç Elibol; Yelda Dere; Ahmet Korkut Belli; Cenk Elibol; Özcan Dere; Okay Nazlı
Journal:  Turk J Surg       Date:  2020-03-18

6.  Vacuum-assisted breast biopsy under ultrasonographic guidance: analysis of a 10-year experience.

Authors:  Seung Hyun Lee; Eun-Kyung Kim; Min Jung Kim; Hee Jung Moon; Jung Hyun Yoon
Journal:  Ultrasonography       Date:  2014-05-21

7.  Ultrasound guided percutaneous microwave ablation of benign breast lesions.

Authors:  Jie Yu; Bao-Hua Chen; Jing Zhang; Zhi-Yu Han; Han Wu; Yan Huang; Meng-Juan Mu; Ping Liang
Journal:  Oncotarget       Date:  2017-05-23

Review 8.  Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy.

Authors:  Vivian Youngjean Park; Eun-Kyung Kim; Hee Jung Moon; Jung Hyun Yoon; Min Jung Kim
Journal:  Ultrasonography       Date:  2017-08-19

9.  Elite VABB 13G: A New Ultrasound-Guided Wireless Biopsy System for Breast Lesions. Technical Characteristics and Comparison with Respect to Traditional Core-Biopsy 14-16G Systems.

Authors:  Daniele La Forgia; Alfonso Fausto; Gianluca Gatta; Graziella Di Grezia; Angela Faggian; Annarita Fanizzi; Daniela Cutrignelli; Rosalba Dentamaro; Vittorio Didonna; Vito Lorusso; Raffaella Massafra; Sabina Tangaro; Maria Antonietta Mazzei
Journal:  Diagnostics (Basel)       Date:  2020-05-09

10.  RESPONDER - diagnosis of pathological complete response by vacuum-assisted biopsy after neoadjuvant chemotherapy in breast Cancer - a multicenter, confirmative, one-armed, intra-individually-controlled, open, diagnostic trial.

Authors:  Joerg Heil; Peter Sinn; Hannah Richter; André Pfob; Benedikt Schaefgen; André Hennigs; Fabian Riedel; Bettina Thomas; Marc Thill; Markus Hahn; Jens-Uwe Blohmer; Sherko Kuemmel; Maria Margarete Karsten; Mattea Reinisch; John Hackmann; Toralf Reimer; Geraldine Rauch; Michael Golatta
Journal:  BMC Cancer       Date:  2018-08-25       Impact factor: 4.430

View more