Vascular response of the segments adjacent to the proximal and distal edges of the ABSORB everolimus-eluting bioresorbable vascular scaffold: 6-month and 1-year follow-up assessment: a virtual histology intravascular ultrasound study from the first-in-man ABSORB cohort B trial.

Bill D Gogas1, Patrick W Serruys, Roberto Diletti, Vasim Farooq, Salvatore Brugaletta, Maria D Radu, Jung Ho Heo, Yoshinobu Onuma, Robert-Jan M van Geuns, Evelyn Regar, Bernard De Bruyne, Bernard Chevalier, Leif Thuesen, Pieter C Smits, Dariusz Dudek, Jacques Koolen, Stefan Windecker, Robert Whitbourn, Karine Miquel-Hebert, Cecile Dorange, Richard Rapoza, Hector M Garcia-Garcia, Dougal McClean, John A Ormiston.   

Abstract

OBJECTIVES: This study sought to investigate in vivo the vascular response at the proximal and distal edges of the second-generation ABSORB everolimus-eluting bioresorbable vascular scaffold (BVS).
BACKGROUND: The edge vascular response after implantation of the BVS has not been previously investigated.
METHODS: The ABSORB Cohort B trial enrolled 101 patients and was divided into B(1) (n = 45) and B(2) (n = 56) subgroups. The adjacent (5-mm) proximal and distal vessel segments to the implanted ABSORB BVS were investigated at either 6 months (B(1)) or 1 year (B(2)) with virtual histology intravascular ultrasound (VH-IVUS) imaging.
RESULTS: At the 5-mm proximal edge, the only significant change was modest constrictive remodeling at 6 months (Δ vessel cross-sectional area: -1.80% [-3.18; 1.30], p < 0.05), with a tendency to regress at 1 year (Δ vessel cross-sectional area: -1.53% [-7.74; 2.48], p = 0.06). The relative change of the fibrotic and fibrofatty (FF) tissue areas at this segment were not statistically significant at either time point. At the 5-mm distal edge, a significant increase in the FF tissue of 43.32% [-19.90; 244.28], (p < 0.05) 1-year post-implantation was evident. The changes in dense calcium need to be interpreted with caution since the polymeric struts are detected as "pseudo" dense calcium structures with the VH-IVUS imaging modality.
CONCLUSIONS: The vascular response up to 1 year after implantation of the ABSORB BVS demonstrated some degree of proximal edge constrictive remodeling and distal edge increase in FF tissue resulting in nonsignificant plaque progression with adaptive expansive remodeling. This morphological and tissue composition behavior appears to not significantly differ from the behavior of metallic drug-eluting stents at the same observational time points.
Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22721662     DOI: 10.1016/j.jcin.2012.02.017

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  5 in total

1.  How far have we come with bioresorbable vascular scaffolds, and where should we go?

Authors:  Jeehoon Kang; Kyung Woo Park; Hyo Soo Kim
Journal:  Cardiovasc Diagn Ther       Date:  2017-06

Review 2.  Methods to assess bioresorbable vascular scaffold devices behaviour after implantation.

Authors:  Alberto Pernigotti; Elisabetta Moscarella; Giosafat Spitaleri; Claudia Scardino; Kohki Ishida; Salvatore Brugaletta
Journal:  J Thorac Dis       Date:  2017-08       Impact factor: 2.895

3.  Scaffold underexpansion and late lumen loss after bioresorbable scaffold implantation: Insights from ABSORB JAPAN trial.

Authors:  Kozo Okada; Yasuhiro Honda; Hideki Kitahara; Masayasu Ikutomi; Ryo Kameda; M Brooke Hollak; Paul G Yock; Jeffrey J Popma; Hajime Kusano; Wai-Fung Cheong; Krishnankutty Sudhir; Peter J Fitzgerald; Takeshi Kimura
Journal:  Int J Cardiol Heart Vasc       Date:  2020-09-04

4.  Coronary bioresorbable stents: Non-invasive quantitative evaluation of intra- and juxta-stent plaque composition-A computed tomography longitudinal study.

Authors:  Evguenia Zdanovich; Samer Mansour; Louis-Mathieu Stevens; Charbel Naim; Daniel Juneau; Alexandre Semionov; Carl Chartrand-Lefebvre
Journal:  PLoS One       Date:  2022-10-13       Impact factor: 3.752

5.  Coronary Aneurysm Formation After Bioresorbable Vascular Scaffold Implantation Resulting in Acute Myocardial Infarction.

Authors:  Ching-Chang Fang; Yeun Tarl Fresner Ng Jao
Journal:  Am J Case Rep       Date:  2017-05-17