Literature DB >> 22720282

Can resonance frequency analysis predict failure risk of immediately loaded implants?

Momen A Atieh1, Nabeel H M Alsabeeha, Alan G T Payne.   

Abstract

PURPOSE: Resonance frequency analysis (RFA) is used to measure oral implant stability. There is controversy with regard to its accuracy in predicting both implant stability and osseointegration. This systematic review and meta-analysis determined the prognostic accuracy of RFA in predicting implant failure following immediate loading protocols.
MATERIALS AND METHODS: MEDLINE, EMBASE, the Cochrane Oral Health Group's Trials Register, the United Kingdom National Research Register, the Australian New Zealand Clinical Trials Registry, the Database of Abstracts of Reviews of Effectiveness, and the Conference Proceedings Citations Index were searched to select studies that used RFA in assessing implant stability prior to immediate loading. The sensitivity, specificity, and accuracy of RFA in the selected studies were evaluated using a random effects model. The summary receiver operating characteristic was constructed to summarize the overall test performance.
RESULTS: Fifteen studies with 2,236 immediately loaded implants were identified. The sensitivity of RFA in predicting failure of immediately loaded implants was 0.38 (95% confidence interval [CI]: 0.22 to 0.56), the specificity was 0.73 (95% CI: 0.71 to 0.75), and the diagnostic odds ratio was 2.10 (95% CI: 0.79 to 5.57). The area under the curve was 0.54, suggesting a poor predictive and discriminative ability.
CONCLUSION: RFA measurement at the time of implant placement is not sufficiently accurate to determine implant stability and osseointegration during immediate loading protocols.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22720282

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  9 in total

1.  Prospective randomized clinical trial of hydrophilic tapered implant placement at maxillary posterior area: 6 weeks and 12 weeks loading.

Authors:  Seong-Beom Kim; Pil-Young Yun; Sang-Yun Kim; Yang-Jin Yi; Ji-Yun Kim; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2016-10-21       Impact factor: 1.904

2.  Resonance frequency analysis of dental implants placed at the posterior maxilla varying the surface treatment only: A randomized clinical trial.

Authors:  Marcelo M Novellino; Newton Sesma; Piero R Zanardi; Dalva C Laganá
Journal:  Clin Implant Dent Relat Res       Date:  2017-06-20       Impact factor: 3.932

3.  Six-implant-supported immediate fixed rehabilitation of atrophic edentulous maxillae with tilted distal implants.

Authors:  S Wentaschek; S Hartmann; C Walter; W Wagner
Journal:  Int J Implant Dent       Date:  2017-07-25

4.  Immediate Loading of Single Implants in the Anterior Maxilla: A 1-Year Prospective Clinical Study on 34 Patients.

Authors:  Miguel Stanley; Filipa Calheiros Braga; Beatriz Mota Jordao
Journal:  Int J Dent       Date:  2017-05-22

5.  Relationship between cortical bone thickness and implant stability at the time of surgery and secondary stability after osseointegration measured using resonance frequency analysis.

Authors:  Kenko Tanaka; Irena Sailer; Ryosuke Iwama; Kensuke Yamauchi; Shinnosuke Nogami; Nobuhiro Yoda; Tetsu Takahashi
Journal:  J Periodontal Implant Sci       Date:  2018-12-27       Impact factor: 2.614

6.  A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants.

Authors:  T P Beena Kumary; Anuj Singh Parihar; Joe Mathew; K Ipe Sabu; Sindhuja Kota Venkata; Prashant Babaji
Journal:  J Int Soc Prev Community Dent       Date:  2019-02-14

7.  Factors Influencing Resonance Frequency Analysis (RFA) Measurements and 5-Year Survival of Neoss Dental Implants.

Authors:  Peter Andersson; Luca Pagliani; Damiano Verrocchi; Stefano Volpe; Herman Sahlin; Lars Sennerby
Journal:  Int J Dent       Date:  2019-04-01

8.  Prospective, Clinical Pilot Study with Eleven 4-Mm Extra-Short Implants Splinted to Longer Implants for Posterior Maxilla Rehabilitation.

Authors:  Daniel Torassa; Pablo Naldini; José Luis Calvo-Guirado; Enrique Fernández-Bodereau
Journal:  J Clin Med       Date:  2020-01-28       Impact factor: 4.241

9.  Tapered, Double-Lead Threads Single Implants Placed in Fresh Extraction Sockets and Healed Sites of the Posterior Jaws: A Multicenter Randomized Controlled Trial with 1 to 3 Years of Follow-Up.

Authors:  Alessandro Cucchi; Elisabetta Vignudelli; Simonetta Franco; Luca Levrini; Dario Castellani; Luca Pagliani; Massimiliano Rea; Claudio Modena; Giulio Sandri; Carlo Longhi
Journal:  Biomed Res Int       Date:  2017-09-13       Impact factor: 3.411

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.