Adjusting a polymer formulation for an optimal bioresorbable stent: a 6-month follow-up study.

Eric Durand1, Mathilde Lemitre, Ludovic Couty, Tahmer Sharkawi, Camille Brasselet, Michel Vert, Antoine Lafont.   

Abstract

AIMS: To assess the impact of the composition in L- and D- of lactic acid stereo copolymers without drug elution on the in situ behaviour of prototype stents in terms of biomechanics and biocompatibility. METHODS AND
RESULTS: PLA50, 75, and 92 stereo-copolymer stents (L/D lactic acid ratio from 1 to 11.5) were processed using the injection moulding facilities of Arterial Remodeling Technologies (Noisy le Roi, France). The resulting 3 mm outer diameter tubes having a diameter at the desired nominal size were laser-cut and crimped on regular angioplasty balloons and chemically sterilised prior to implantation in iliac rabbit arteries. Acute recoil was higher in PLA50 and PLA75 stent-treated arteries than in those with PLA92 stents (17.4 ± 11.4 vs. 13.5 ± 7.6 vs. 4.1 ± 3.8 %, respectively, p=0.001). At one month, in-stent area was higher in PLA92 than in PLA50 and PLA75 stented arteries (5.9 ± 0.6 vs. 1.6 ± 1.6 vs. 2.6 ± 3.2 mm², respectively, p<0.001). Re-endothelialisation was complete, and inflammation was mild around the struts, similar among the three stents. Late lumen loss and neointimal area were low and similar in PLA92 stent-treated arteries one and six months after angioplasty (0.2 ± 0.2 vs. 0.3 ± 0.2 mm, p=0.60; 0.5 ± 0.5 vs. 0.5 ± 0.8 mm², p=0.72, respectively). At six months, inflammation decreased compared to one-month follow-up (1.4 ± 0.5 vs. 0.6 ± 0.5, p=0.006).
CONCLUSIONS: A stereo-copolymer composition strongly influences biomechanical properties of PLA bioresorbable stents in agreement with what has been known for a long time from other applications, but not biocompatibility. PLA92 stents appeared as presenting acceptable acute deployment and 6-month favourable outcome in the rabbit model despite the absence of drugs.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22717927     DOI: 10.4244/EIJV8I2A38

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  5 in total

Review 1.  The effects of novel, bioresorbable scaffolds on coronary vascular pathophysiology.

Authors:  Michael J Lipinski; Ricardo O Escarcega; Thibault Lhermusier; Ron Waksman
Journal:  J Cardiovasc Transl Res       Date:  2014-05-07       Impact factor: 4.132

Review 2.  New generation bioresorbable scaffold technologies: an update on novel devices and clinical results.

Authors:  Damiano Regazzoli; Pier Pasquale Leone; Antonio Colombo; Azeem Latib
Journal:  J Thorac Dis       Date:  2017-08       Impact factor: 2.895

Review 3.  New-Generation Coronary Stents: Current Data and Future Directions.

Authors:  Ankur Kalra; Hasan Rehman; Sahil Khera; Braghadheeswar Thyagarajan; Deepak L Bhatt; Neal S Kleiman; Robert W Yeh
Journal:  Curr Atheroscler Rep       Date:  2017-03       Impact factor: 5.113

Review 4.  Bioresorbable scaffolds: a new paradigm in percutaneous coronary intervention.

Authors:  Erhan Tenekecioglu; Vasim Farooq; Christos V Bourantas; Rafael Cavalcante Silva; Yoshinobu Onuma; Mustafa Yılmaz; Patrick W Serruys
Journal:  BMC Cardiovasc Disord       Date:  2016-02-12       Impact factor: 2.298

5.  Biodegradable Flow Diverter for the Treatment of Intracranial Aneurysms: A Pilot Study Using a Rabbit Aneurysm Model.

Authors:  Hidehisa Nishi; Akira Ishii; Isao Ono; Yu Abekura; Hiroyuki Ikeda; Daisuke Arai; Yukihiro Yamao; Masakazu Okawa; Takayuki Kikuchi; Akiyoshi Nakakura; Susumu Miyamoto
Journal:  J Am Heart Assoc       Date:  2019-10-04       Impact factor: 5.501

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.