Literature DB >> 22712080

Single-step radiofluorination of peptides using continuous flow microreactor.

Svetlana V Selivanova1, Linjing Mu, Johanna Ungersboeck, Timo Stellfeld, Simon M Ametamey, Roger Schibli, Wolfgang Wadsak.   

Abstract

18F radiolabelling of peptides bearing two different prosthetic groups was successfully conducted in a continuous flow microfluidic device for the first time. Radiochemical yields were dependent on precursor concentration, reaction temperature and flow rate. The choice of leaving group had a dramatic influence on the reaction outcome. Rapid reaction optimization was possible.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22712080     DOI: 10.1039/c2ob00015f

Source DB:  PubMed          Journal:  Org Biomol Chem        ISSN: 1477-0520            Impact factor:   3.876


  3 in total

Review 1.  The Current Role of Microfluidics in Radiofluorination Chemistry.

Authors:  Karla-Anne Knapp; Michael L Nickels; H Charles Manning
Journal:  Mol Imaging Biol       Date:  2020-06       Impact factor: 3.488

Review 2.  Microfluidics for synthesis of peptide-based PET tracers.

Authors:  Yang Liu; Mei Tian; Hong Zhang
Journal:  Biomed Res Int       Date:  2013-10-31       Impact factor: 3.411

3.  Development and implementation of ISAR, a new synthesis platform for radiopharmaceutical production.

Authors:  Christopher Frank; Georg Winter; Fredrik Rensei; Victor Samper; Allen F Brooks; Brian G Hockley; Bradford D Henderson; Christian Rensch; Peter J H Scott
Journal:  EJNMMI Radiopharm Chem       Date:  2019-09-18
  3 in total