Literature DB >> 22708915

Standard terminologies for photoplethysmogram signals.

Mohamed Elgendi1.   

Abstract

Photoplethysmography is one of the optical techniques has been developed for experimental use in vascular disease. It has several advantages over other traditional experimental approaches. Because of its non-invasive, safe, costeffective and easy-to-use properties, it is considered as a useful diagnostic tool. The further developments in the Photoplethysmograph may replace it among other tools used in the assessment of vascular diseases such as blood test and ultrasound. This overview discusses the different terminologies used for the photoplethysmograph and reveals the research discontinuity among different disciplines. Moreover, it suggests standard terminologies as a resolution for a confusion persisted for more than 50 years.

Entities:  

Mesh:

Year:  2012        PMID: 22708915      PMCID: PMC3465827          DOI: 10.2174/157340312803217184

Source DB:  PubMed          Journal:  Curr Cardiol Rev        ISSN: 1573-403X


INTRODUCTION

Photoplethysmography reflects the blood movement in the vessel, which goes from the heart to the fingertips through the blood vessels in a wave-like motion [1], as shown in Fig. (). It is an optical measurement technique uses an invisible infrared light send in the tissue and the amount of the backscattered light corresponds with the variation of the blood volume [2]. The photoplethysmography (PPG), introduced by Hertzman in 1938 [3], is mainly reflects the blood volume changes in the finger arterioles. It has been recognized as non-invasive, simple, reliable, and cost-effective method of measuring arterial pulse waves in relation to changes in wave amplitude. Therefore, it is considered as a fast developing tool which easily can replace other traditional tools used in the vascular disease assessment such blood test, ultrasound, Doppler, Magnetic resonance angiography and computed tomography angioraphy. However, the wave contour itself has not been analyzed because of the difficulty in detecting minute changes in the phase of the inflections. In 1978, Ozawa reported (in Japanese) [4] that the second derivative of the photoplethysmogram wave has characteristic contours (waves) that facilitated the interpretation of the original photoplethysmogram waves, as shown in Fig. (). Therefore, the second derivative of the photoplethysmogram was developed as a method allowing more accurate recognition of the inflection points and easier interpretation of the original plethysmogram wave. The original photoplethysmogram wave form consists of two waves: systolic and diastolic waves, as shown Fig. (). The second derivative of the original photoplethysmogram waveform includes four systolic waves and one diastolic wave, namely -wave (early systolic positive wave), -wave (early systolic negative wave), -wave (late systolic reincreasing wave), -wave (late systolic redecreasing wave) and -wave (early diastolic positive wave), as shown Fig. (). Although the usage of photoplethysmography has been increasing in science and engineering during the past 50 years, there is still a lack of common terminologies for photoplethysmograph and its second derivative signals. This has caused substantial confusion and disagreement during discussions in literature and in interpretation of the large number of publications in both area science and engineering. This may waste the researcher’s efforts by generating redundant results and also may limit the scientific progress in this multidisciplinary field. This overview discusses the different plethysmography terminologies and proposes common terminologies to resolve the difficulties and confusion between scientific communities.

METHODOLOGY

Photoplethysmogram

Some of the literature review to explain the different usage of different terminologies for photoplethysmogram:

Digital Velocity Pulse (DVP)

In 2002, Millasseau et al. [6] used the DVP terminology when they provided a simple, reproducible, non-invasive measure of large artery stiffness using the contour analysis of the DVP. In 2006, Padilla et al. [7] used the DVP terminology when they suggested a useful relation among the stiffness index SIDVP = h / ΔTDVP obtainedobtained of simple form by DVP and the ankle-brachial pulse wave velocity (abPWV), as well as the values of sanguineous pressure, whereas abPWV = Lab / ΔT , and Lab measured distance between ankle-brachial location. In 2007, Alty et al. [8] used the DVP terminology when they developed a method to accurately classify subjects into high and low PWV (equivalent to high and low CVD risk) using features extracted from their DVP waveform has been presented.

Plethysmogram (PTG)

In 1999, Mishima et al. [9] used the PTG terminology they found the increase in mean RR interval and the decrease in baseline deflection of the PTG strongly correlates of autogenic training. In 2005, Yashima et al. [10] used the PTG terminology when they proposed a new stress evaluation technique using the photoplethysmogram (PTG) by applying Morlet wavelets. In 2007, Kageyama et al. [11] used the PTG terminology when they performed wavelet analysis of the finger-tip photo-plethysmogram (PTG) in order to quantify the stress stage.

Photoplethysmogram (PPG)

In 2008, Abe et al. [12] used the PPG terminology when they proposed a method for evaluating effects of visually-induced motion sickness using ICA for Photoplethysmography (PPG). In 2008, Cox et al. [13] used the PPG terminology when they proposed the use of photoplethysmogram (PPG) morphology as an indicator of hypovolemic states and its correlation with blood pressure. In 2009, Gil et al. [14] used the PPG terminology when they analysed the heart rate variability (HRV) during decreases in the amplitude fluctuations of photopletysmography (PPG) events for obstructive sleep apnea syndrome screening.

Second Derivative Photoplethysmogram

Some of the literature review to explain the different usage of different terminologies for the second derivative plethysmogram:

Second Derivative Photoplethysmogram (SDPTG)

In 1998, Takazawa et al. [4] used the SDPTG terminology when they demonstrated that the b/a ratio reflects increased arterial stiffness, hence the b/a ratio increases with age. Moreover, they found the (b-c-d-e)/a ratio may be useful for evaluation of vascular aging and for screening of arteriosclerotic disease. The waves a, b, c, d, and e are demonstrated in Fig. (). In 1998, Imanaga et al. [15] used the SDPTG terminology when they provided a direct evidence that magnitude of b/a of the APG is related to the distensibility of the peripheral artery, and suggest that magnitude of b/a is a useful non-invasive index of atherosclerosis and altered arterial distensibility. In 2007, Baek et al. [16] used the SDPTG terminology when they confirmed that the b/a ratio and the aging index (SDPTG-AI) increased with age, and the c/a, d/a, and e/a ratios decreased with age. The informal aging index (b-e)/a has been suggested as a replacement for the known formula (b-c-d-e)/a. In 2007, Kimura et al. [17] used the SDPTG terminology when they proposed a the efficacy of Kamishoyosan herb for patients with Premenstrual syndrome was quantitatively ascertained using the APG.

Acceleration Photoplethysmogram (APG)

In 1994, Katsuki et al. [18] used the APG terminology when they suggested that the present APG index is adequate about the individual reproducibility, and it has the possibility to apply as an index of arteriosclerosis. In 1996, Takada et al. [19] used the APG terminology when they concluded that simply categorized wave patterns of APG could be a useful noninvasive tool to evaluate aging in cardiovascular system. In 2000, Bortolotto [20] used the APG terminology when they introduced the APG Age Index as a useful measure for evaluation of vascular aging in hypertensives. In 2005,Ushiroyama et al. [21] used the APG terminology when they reported that patients with a sensation of coldness showed an improvement of the APG index (b - c - d)/a upon Sho treatment, which includes Kamishoyosan. Sho is one of the main concepts of Kampo medicine, and corresponds to the holistic tailored treatment suitable for the individual patient’s symptoms. In 2006, Nousou et al. [22] used the APG terminology when they developed a diagnosis assistance system with a light load to the testee. This system measures the acceleration plethysmogram and reproduces the diagnosis by using Self-Organizing Maps. In 2007, Taniguchi et al. [23] used the APG terminology when they proposed a method for using the APG variability to evaluate the surgeon's stress in his/her using a surgical assistant system. In 2008, Fujimoto et al. [24] used the APG terminology when they proposed a possibility to diagnosis of stress by accelerated plethysmogram applied the criterion which combines two evaluation based on chaos theory; trajectory parallel measure method and size of neighbourhood space in chaos attractor.

Second Derivative Digital Velocity Pulse (SDDVP)

To date, two papers have been found using the SDDVP. The first by Millasseau et al. in 2003 [25] when they used the photoplethysmogram to examine the vascular impact of aging and vasoactive drugs. The second paper by Rivas-Vilchis et al. in 2007, [26] when they used the photoplethysmogram to assess the vascular effects of PC6 (Neiguan) in healthy and hypertensive subjects. In 2007, Taniguchi et al. [23] used the APG terminology when they proposed a method for using the Several general preferences regarding standard terminologies for Photoplethysmogram signals have been introduced as following: Standardization of Photoplethysmogram terminologies is highly desirable. Each terminology system should be as simple as possible and has been used the most in literature. The symbols should indicate the nature of the Photoplethysmogram signal type. A symbol representing a given charge should not be easily confused with any of those representing the other biomedical signals types. Various sets of symbols were proposed and problems associated with each set were noted as following: Photoplethysmograph, Photoplethysmogram,and Digital Pulse Volume are the same terminologies with different a symbol PTG, PPG, and DVP. Second Derivative Photoplethysmograph, Acceleration Photoplethysmograph are the same terminologies with different symbols SDPTG, and APG.

SEARCH STRATEGY

The data collected from PubMed database has been used for English literature and ScienceLinksJapan for Japanese literature. The reason behind choosing the PubMed database, it comprises more than 19 million citations for biomedical articles from MEDLINE and life science journals back to 1948. PubMed includes links to full-text articles which may be found in other databases such as PubMed Central or at publisher web sites. The total number of references for “Photoplethysmography” terminology was 1024, “Photoplethysmogram” was 91, “PPG”was 232, “PTG”was 13, “DVP” was 10, “APG” was 4, and “SDPTG” was 15 in PUBMED database. On the other hand, the total number of references for “Photoplethysmography” terminology was 23, “Photoplethysmogram” was 24, “PPG”was 2, “PTG”was 4, “DVP” was 8, “APG” was 28, and “SDPTG” was 8 in SCIENCELINKS Japanese database. As shown in Fig. (); the number of publications for “PPG” is increasing with years more than “PTG” and “DVP”. In Fig. (), the cumulative sum of PPG clearly shows an exponential increase through years. As shown in Fig. (); the number of publications for “APG” is increasing with years more than “SDPTG”. In Fig. (), the cumulative sum of APG clearly shows an exponential increase through years. By categorizing the number of publication by its discipline, it is interesting to notice in Fig. () that the usage of “PPG “,”PTG”, and “DVP” terminologies is more in Engineering than science “SDPTG”. In Fig. (), the usage of “APG” and “SDPTG” vanishes in Engineering compared to Science. The significant result in Fig. () shows that all Photoplethysmography terminologies are coherent between PubMed and ScienceLinksJapan in all terminologies except APG. APG has been used by Japanese scientist more than western scientist. Therefore, the recommended as standard naming for the discussed terminologies is:

CONCLUSION

The author suggests to all scientists and engineers active in photoplethymogram work to use PPG (for photoplethysmogram) and APG (for the second derivative photoplethysmogram) terminologies in oral presentations and written publications. The usage of different terminologies for the same signal can lead to a disconnect between different groups of engineers and scientists. These standard terminologies will save the researcher’s efforts and overcome generating redundant results. It will also speed up the scientific progress in this multidisciplinary field. This paper is an attempt to resolve the difficulties and confusion regarding plethysmography terminologies which have persisted for more than 50 years.
TerminologyAcronym
Photoplethysmography PhotoplethysmogramDigital Velocity PulsePPG
Second Derivative PhotoplethysmographySecond Derivative PhotoplethysmogramSecond Derivative Digital Velocity PulseAcceleration PlethysmographyAPG
  18 in total

1.  Correlation between wave components of the second derivative of plethysmogram and arterial distensibility.

Authors:  I Imanaga; H Hara; S Koyanagi; K Tanaka
Journal:  Jpn Heart J       Date:  1998-11

2.  Assessment of the vascular effects of PC6 (Neiguan) using the second derivative of the finger photoplethysmogram in healthy and hypertensive subjects.

Authors:  José F Rivas-Vilchis; Fernando Hernández-Sánchez; Ramón González-Camarena; Luis D Suárez-Rodríguez; Ricardo Escorcia-Gaona; Jorge A Cervantes-Reyes; Rubén Román-Ramos
Journal:  Am J Chin Med       Date:  2007       Impact factor: 4.667

3.  Application of wavelet analysis to the plethysmogram for the evaluation of mental stress.

Authors:  K Yashima; T Sasaki; Y Kageyama; M Odagaki; H Hosaka
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2005

4.  Wavelet analysis for quantification of mental stress stage by finger-tip photo-plethysmography.

Authors:  Y Kageyama; M Odagaki; H Hosaka
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2007

5.  Predicting arterial stiffness from the digital volume pulse waveform.

Authors:  Stephen R Alty; Natalia Angarita-Jaimes; Sandrine C Millasseau; Philip J Chowienczyk
Journal:  IEEE Trans Biomed Eng       Date:  2007-12       Impact factor: 4.538

6.  [A new index of acceleration plethysmogram and its clinical physiological evaluation].

Authors:  K Katsuki; T Yamamoto; T Yuuzu; H Tanaka; R Okano; K Hirata; M Miyachi; S Onodera; M Ono
Journal:  Nihon Seirigaku Zasshi       Date:  1994

7.  Assessment of vasoactive agents and vascular aging by the second derivative of photoplethysmogram waveform.

Authors:  K Takazawa; N Tanaka; M Fujita; O Matsuoka; T Saiki; M Aikawa; S Tamura; C Ibukiyama
Journal:  Hypertension       Date:  1998-08       Impact factor: 10.190

8.  Discrimination of sleep-apnea-related decreases in the amplitude fluctuations of PPG signal in children by HRV analysis.

Authors:  Eduardo Gil; Martín Mendez; José María Vergara; Sergio Cerutti; Anna Maria Bianchi; Pablo Laguna
Journal:  IEEE Trans Biomed Eng       Date:  2008-11-11       Impact factor: 4.538

9.  A method for evaluating effects of visually-induced motion sickness using ICA for photoplethysmography.

Authors:  Makoto Abe; Makoto Yoshizawa; Norihiro Sugita; Akira Tanaka; Shigeru Chiba; Tomoyuki Yambe; Shin-Ichi Nitta
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

Review 10.  On the analysis of fingertip photoplethysmogram signals.

Authors:  Mohamed Elgendi
Journal:  Curr Cardiol Rev       Date:  2012-02
View more
  11 in total

1.  Digital Photoplethysmography for Assessment of Arterial Stiffness: Repeatability and Comparison with Applanation Tonometry.

Authors:  Emma von Wowern; Gerd Östling; Peter M Nilsson; Per Olofsson
Journal:  PLoS One       Date:  2015-08-20       Impact factor: 3.240

2.  Detection of a and b waves in the acceleration photoplethysmogram.

Authors:  Mohamed Elgendi; Ian Norton; Matt Brearley; Derek Abbott; Dale Schuurmans
Journal:  Biomed Eng Online       Date:  2014-09-25       Impact factor: 2.819

3.  On Time Domain Analysis of Photoplethysmogram Signals for Monitoring Heat Stress.

Authors:  Mohamed Elgendi; Rich Fletcher; Ian Norton; Matt Brearley; Derek Abbott; Nigel H Lovell; Dale Schuurmans
Journal:  Sensors (Basel)       Date:  2015-09-25       Impact factor: 3.576

4.  A Pulse Rate Detection Method for Mouse Application Based on Multi-PPG Sensors.

Authors:  Shu-Tyng Lin; Wei-Hao Chen; Yuan-Hsiang Lin
Journal:  Sensors (Basel)       Date:  2017-07-14       Impact factor: 3.576

5.  Optimal Signal Quality Index for Photoplethysmogram Signals.

Authors:  Mohamed Elgendi
Journal:  Bioengineering (Basel)       Date:  2016-09-22

6.  Toward Generating More Diagnostic Features from Photoplethysmogram Waveforms.

Authors:  Mohamed Elgendi; Yongbo Liang; Rabab Ward
Journal:  Diseases       Date:  2018-03-11

7.  How Effective Is Pulse Arrival Time for Evaluating Blood Pressure? Challenges and Recommendations from a Study Using the MIMIC Database.

Authors:  Yongbo Liang; Derek Abbott; Newton Howard; Kenneth Lim; Rabab Ward; Mohamed Elgendi
Journal:  J Clin Med       Date:  2019-03-11       Impact factor: 4.241

8.  Comparison of the ankle-brachial index with parameters of stiffness and peripheral arterial resistance assessed by photoplethysmography in elderly patients.

Authors:  Kelser de Souza Kock; João Batista Ferreira da Silva; Jefferson Luiz Brum Marques
Journal:  J Vasc Bras       Date:  2019-05-15

9.  Systolic peak detection in acceleration photoplethysmograms measured from emergency responders in tropical conditions.

Authors:  Mohamed Elgendi; Ian Norton; Matt Brearley; Derek Abbott; Dale Schuurmans
Journal:  PLoS One       Date:  2013-10-22       Impact factor: 3.240

Review 10.  Advances in Photopletysmography Signal Analysis for Biomedical Applications.

Authors:  Jermana L Moraes; Matheus X Rocha; Glauber G Vasconcelos; José E Vasconcelos Filho; Victor Hugo C de Albuquerque; Auzuir R Alexandria
Journal:  Sensors (Basel)       Date:  2018-06-09       Impact factor: 3.576

View more