Literature DB >> 22708898

Impact of experimental conditions on noncontact laser recordings in microvascular studies.

Guillaume Mahé1, Sylvain Durand, Anne Humeau-Heurtier, Georges Leftheriotis, Pierre Abraham.   

Abstract

Microcirculation, especially skin microcirculation, is a window toward systemic vascular function in magnitude and underlying mechanisms. Different techniques have been developed to assess the microcirculation. Among these techniques, laser technology is used to perform noninvasive microvascular assessments. In the 1970s, the laser Doppler flowmetry (LDF) technique was proposed to monitor microvascular blood flow. More recently, noncontact technologies including laser Doppler perfusion imaging (LDI) and laser speckle contrast imaging (LSCI) have improved the reproducibility of the microcirculation measurements and facilitated some clinical evaluations such as on wounds and ulcers. However, due to the absence of contact between tissue and sensors, it is likely that different technical and environmental conditions may interfere with microvascular recordings. This review presents major technical and environmental conditions, which may interfere with noncontact laser recordings in microvascular studies.
© 2012 John Wiley & Sons Ltd.

Entities:  

Mesh:

Year:  2012        PMID: 22708898     DOI: 10.1111/j.1549-8719.2012.00205.x

Source DB:  PubMed          Journal:  Microcirculation        ISSN: 1073-9688            Impact factor:   2.628


  8 in total

1.  Cutaneous microvascular functional assessment during exercise: a novel approach using laser speckle contrast imaging.

Authors:  G Mahe; P Abraham; A Le Faucheur; A Bruneau; A Humeau-Heurtier; S Durand
Journal:  Pflugers Arch       Date:  2013-01-18       Impact factor: 3.657

2.  Cortisol level after dexamethasone suppression test in patients with non-functioning adrenal incidentaloma is positively associated with the duration of reactive hyperemia response on microvascular bed.

Authors:  M P de Paula; A B Moraes; M das Graças Coelho de Souza; E M R Cavalari; R C Campbell; G da Silva Fernandes; M L F Farias; L M C Mendonça; M Madeira; E Bouskela; L G Kraemer-Aguiar; L Vieira Neto
Journal:  J Endocrinol Invest       Date:  2020-07-19       Impact factor: 4.256

3.  Endothelial dysfunction is present only in the microvasculature and microcirculation of early diffuse systemic sclerosis patients.

Authors:  R T Domsic; C Dezfulian; Al Shoushtari; D Ivanco; E Kenny; C K Kwoh; T A Medsger; H C Champion
Journal:  Clin Exp Rheumatol       Date:  2014-11-05       Impact factor: 4.473

4.  Reproducibility of non-invasive assessment of skin endothelial function using laser Doppler flowmetry and laser speckle contrast imaging.

Authors:  Cyril Puissant; Pierre Abraham; Sylvain Durand; Anne Humeau-Heurtier; Sébastien Faure; Georges Lefthériotis; Pascal Rousseau; Guillaume Mahé
Journal:  PLoS One       Date:  2013-04-19       Impact factor: 3.240

5.  Neurovascular microcirculatory vasodilation mediated by C-fibers and Transient receptor potential vanilloid-type-1 channels (TRPV 1) is impaired in type 1 diabetes.

Authors:  P Marche; S Dubois; P Abraham; E Parot-Schinkel; L Gascoin; A Humeau-Heurtier; P H Ducluzeau; G Mahe
Journal:  Sci Rep       Date:  2017-03-13       Impact factor: 4.379

6.  Motion Tracking System for Robust Non-Contact Blood Perfusion Sensor.

Authors:  Masaaki Hashimoto; Yoshihiro Taguchi
Journal:  Sensors (Basel)       Date:  2018-01-18       Impact factor: 3.576

7.  A Novel Approach to Overcome Movement Artifact When Using a Laser Speckle Contrast Imaging System for Alternating Speeds of Blood Microcirculation.

Authors:  Shayan Bahadori; Tikki Immins; Thomas W Wainwright
Journal:  J Vis Exp       Date:  2017-08-30       Impact factor: 1.355

Review 8.  Clinical applications of laser speckle contrast imaging: a review.

Authors:  Wido Heeman; Wiendelt Steenbergen; Gooitzen van Dam; E Christiaan Boerma
Journal:  J Biomed Opt       Date:  2019-08       Impact factor: 3.758

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.