Literature DB >> 22704592

Bone anchor systems for orthodontic application: a systematic review.

W K Tsui1, H D P Chua, L K Cheung.   

Abstract

This systematic review was performed to investigate the usefulness and clinical effectiveness of skeletal anchorage devices to determine the most effective bone anchor system for orthodontic tooth movement. Literature on bone anchorage devices was selected from PubMed and the Cochrane Library from January 1966 to June 2010. 55 publications regarding miniplates, miniscrews, palatal implants and dental implants as orthodontic anchorage were identified for further analysis. All bone anchorage devices were found to have relatively high success rates and demonstrated their ability to provide absolute anchorage for orthodontic tooth movement. Significant tooth movement could be achieved with low morbidities and good patient acceptance. The reported success rates for the four groups of anchorage systems were generally high with slight variability (miniplates 91.4-100%; palatal implants 74-93.3%; miniscrews 61-100%; dental implants 100%). It was concluded that bone anchorage systems can achieve effective orthodontic movement with low morbidities. The success rate is generally high with slight variability between miniplates, palatal implants, miniscrews and dental implants. Owing to the lack of randomized controlled trials, there is no strong evidence to confirm which bone anchor system is the most effective for orthodontic tooth movement.
Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22704592     DOI: 10.1016/j.ijom.2012.05.011

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  12 in total

Review 1.  Reinforcement of anchorage during orthodontic brace treatment with implants or other surgical methods.

Authors:  Safa Jambi; Tanya Walsh; Jonathan Sandler; Philip E Benson; Richard M Skeggs; Kevin D O'Brien
Journal:  Cochrane Database Syst Rev       Date:  2014-08-19

2.  Comparison between microporous and nanoporous orthodontic miniscrews : An experimental study in rabbits.

Authors:  Yueh-Tse Lee; Eric Jein-Wein Liou; Sinn-Wen Chen
Journal:  J Orofac Orthop       Date:  2022-05-20       Impact factor: 1.938

3.  Induced ankylosis of a primary molar for skeletal anchorage in the mandible as alternative to mini-implants.

Authors:  Matina V Angelopoulou; Despina Koletsi; George Vadiakas; Demetrios J Halazonetis
Journal:  Prog Orthod       Date:  2015-06-18       Impact factor: 2.750

4.  Influence of interradicular and palatal placement of orthodontic mini-implants on the success (survival) rate.

Authors:  Jan Hourfar; Dirk Bister; Georgios Kanavakis; Jörg Alexander Lisson; Björn Ludwig
Journal:  Head Face Med       Date:  2017-06-14       Impact factor: 2.151

5.  Correlation between tooth size-arch length discrepancy and interradicular distances measured on CBCT and panoramic radiograph: an evaluation for miniscrew insertion.

Authors:  Michele Tepedino; Marie A Cornelis; Claudio Chimenti; Paolo M Cattaneo
Journal:  Dental Press J Orthod       Date:  2018 Sep-Oct

6.  In-vitro evaluation of the effects of insertion and sterilization procedures on the mechanical and surface characteristics of mini screws.

Authors:  Civan Aved Hergel; Yasemin Bahar Acar; Mustafa Ates; Nazan Kucukkeles
Journal:  Eur Oral Res       Date:  2019-01-01

7.  Fully customized placement of orthodontic miniplates: a novel clinical technique.

Authors:  Jan Hourfar; Georgios Kanavakis; Peter Goellner; Björn Ludwig
Journal:  Head Face Med       Date:  2014-05-03       Impact factor: 2.151

8.  Temporary anchorage device usage: a survey among Swiss orthodontists.

Authors:  Goran Markic; Christos Katsaros; Nikolaos Pandis; Theodore Eliades
Journal:  Prog Orthod       Date:  2014-04-01       Impact factor: 2.750

Review 9.  Treatment Options for Class III Malocclusion in Growing Patients with Emphasis on Maxillary Protraction.

Authors:  Zeinab Azamian; Farinaz Shirban
Journal:  Scientifica (Cairo)       Date:  2016-04-10

10.  Average interradicular sites for miniscrew insertion: should dental crowding be considered?

Authors:  Michele Tepedino; Paolo M Cattaneo; Francesco Masedu; Claudio Chimenti
Journal:  Dental Press J Orthod       Date:  2017 Sep-Oct
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.