Literature DB >> 22704550

Transplantation of an allogeneic vein bioengineered with autologous stem cells: a proof-of-concept study.

Michael Olausson1, Pradeep B Patil, Vijay Kumar Kuna, Priti Chougule, Nidia Hernandez, Ketaki Methe, Carola Kullberg-Lindh, Helena Borg, Hasse Ejnell, Suchitra Sumitran-Holgersson.   

Abstract

BACKGROUND: Extrahepatic portal vein obstruction can have severe health consequences. Variceal bleeding associated with this disorder causes upper gastrointestinal bleeding, leading to substantial morbidity and mortality. We report the clinical transplantation of a deceased donor iliac vein graft repopulated with recipient autologous stem cells in a patient with extrahepatic portal vein obstruction.
METHODS: A 10 year old girl with extrahepatic portal vein obstruction was admitted to the Sahlgrenska University Hospital in Gothenburg, Sweden, for a bypass procedure between the superior mesenteric vein and the intrahepatic left portal vein (meso Rex bypass). A 9 cm segment of allogeneic donor iliac vein was decellularised and subsequently recellularised with endothelial and smooth muscle cells differentiated from stem cells obtained from the bone marrow of the recipient. This graft was used because the patient's umbilical vein was not suitable and other strategies (eg, liver transplantation) require lifelong immunosuppression.
FINDINGS: The graft immediately provided the recipient with a functional blood supply (25-30 cm/s in the portal vein and 40 mL/s in the artery was measured intraoperatively and confirmed with ultrasound). The patient had normal laboratory values for 9 months. However, at 1 year the blood flow was low and, on exploration, the shunt was patent but too narrow due to mechanical obstruction of tissue in the mesocolon. Once the tissue causing the compression was removed the graft dilated. We therefore used a second stem-cell populated vein graft to lengthen the previous graft. After this second operation, the portal pressure was reduced from 20 mm Hg to 13 mm Hg and blood flow was 25-40 cm/s in the portal vein. With restored portal circulation the patient has substantially improved physical and mental function and growth. The patient has no anti-endothelial cell antibodies and is receiving no immunosuppressive drugs.
INTERPRETATION: An acellularised deceased donor vein graft recellularised with autologous stem cells can be considered for patients in need of vascular vein shunts without the need for immunosuppression. FUNDING: Swedish Government.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22704550     DOI: 10.1016/S0140-6736(12)60633-3

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  44 in total

Review 1.  Tissue-Engineering Approaches to Restore Kidney Function.

Authors:  Ravi Katari; Lauren Edgar; Theresa Wong; Angela Boey; Sarah Mancone; Daniel Igel; Tyler Callese; Marcia Voigt; Riccardo Tamburrini; Joao Paulo Zambon; Laura Perin; Giuseppe Orlando
Journal:  Curr Diab Rep       Date:  2015-10       Impact factor: 4.810

Review 2.  Tissue Engineering at the Blood-Contacting Surface: A Review of Challenges and Strategies in Vascular Graft Development.

Authors:  Daniel Radke; Wenkai Jia; Dhavan Sharma; Kemin Fena; Guifang Wang; Jeremy Goldman; Feng Zhao
Journal:  Adv Healthc Mater       Date:  2018-05-07       Impact factor: 9.933

Review 3.  Will regenerative medicine replace transplantation?

Authors:  Giuseppe Orlando; Shay Soker; Robert J Stratta; Anthony Atala
Journal:  Cold Spring Harb Perspect Med       Date:  2013-08-01       Impact factor: 6.915

4.  Spatial patterning of endothelial cells and vascular network formation using ultrasound standing wave fields.

Authors:  Kelley A Garvin; Diane Dalecki; Mohammed Yousefhussien; Maria Helguera; Denise C Hocking
Journal:  J Acoust Soc Am       Date:  2013-08       Impact factor: 1.840

5.  Preclinical Liver Bud Engineering towards Clinical Target for Liver Diseases.

Authors:  Shibashish Giri; Augustinus Bader
Journal:  J Clin Exp Hepatol       Date:  2014-04-18

6.  Optimum parameters for freeze-drying decellularized arterial scaffolds.

Authors:  William S Sheridan; Garry P Duffy; Bruce P Murphy
Journal:  Tissue Eng Part C Methods       Date:  2013-06-25       Impact factor: 3.056

7.  Novel application and serial evaluation of tissue-engineered portal vein grafts in a murine model.

Authors:  Mark W Maxfield; Mitchel R Stacy; Hirotsugu Kurobe; Shuhei Tara; Tai Yi; Muriel A Cleary; Zhen W Zhuang; Manuel I Rodriguez-Davalos; Sukru H Emre; Yasuko Iwakiri; Toshiharu Shinoka; Christopher K Breuer
Journal:  Regen Med       Date:  2017-12-07       Impact factor: 3.806

Review 8.  Controlled protein delivery in the generation of microvascular networks.

Authors:  Jillian W Andrejecsk; William G Chang; Jordan S Pober; W Mark Saltzman
Journal:  Drug Deliv Transl Res       Date:  2015-04       Impact factor: 4.617

9.  Cryo-chemical decellularization of the whole liver for mesenchymal stem cells-based functional hepatic tissue engineering.

Authors:  Wei-Cheng Jiang; Yu-Hao Cheng; Meng-Hua Yen; Yin Chang; Vincent W Yang; Oscar K Lee
Journal:  Biomaterials       Date:  2014-01-24       Impact factor: 12.479

10.  Recellularization of acellular human small intestine using bone marrow stem cells.

Authors:  Pradeep B Patil; Priti B Chougule; Vijay K Kumar; Stefan Almström; Henrik Bäckdahl; Debashish Banerjee; Gustaf Herlenius; Michael Olausson; Suchitra Sumitran-Holgersson
Journal:  Stem Cells Transl Med       Date:  2013-03-13       Impact factor: 6.940

View more