Literature DB >> 22703837

Discrimination between glycosylation patterns of therapeutic antibodies using a microfluidic platform, MALDI-MS and multivariate statistics.

Tran Thi Thuy1, Erik Tengstrand, Magnus Aberg, Gunnar Thorsén.   

Abstract

Optimal glycosylation with respect to the efficacy, serum half-life time, and immunogenic properties is essential in the generation of therapeutic antibodies. The glycosylation pattern can be affected by several different parameters during the manufacture of antibodies and may change significantly over cultivation time. Fast and robust methods for determination of the glycosylation patterns of therapeutic antibodies are therefore needed. We have recently presented an efficient method for the determination of glycans on therapeutic antibodies using a microfluidic CD platform for sample preparation prior to matrix-assisted laser-desorption mass spectrometry analysis. In the present work, this method is applied to analyse the glycosylation patterns of three commercially available therapeutic antibodies and one intended for therapeutic use. Two of the antibodies produced in mouse myeloma cell line (SP2/0) and one produced in Chinese hamster ovary (CHO) cells exhibited similar glycosylation patterns but could still be readily differentiated from each other using multivariate statistical methods. The two antibodies with most similar glycosylation patterns were also studied in an assessment of the method's applicability for quality control of therapeutic antibodies. The method presented in this paper is highly automated and rapid. It can therefore efficiently generate data that helps to keep a production process within the desired design space or assess that an identical product is being produced after changes to the process.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22703837     DOI: 10.1016/j.jpba.2012.05.020

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  2 in total

1.  Glycosylation profiling of therapeutic antibodies in serum samples using a microfluidic CD platform and MALDI-MS.

Authors:  Tran Thi Thuy; Gunnar Thorsén
Journal:  J Am Soc Mass Spectrom       Date:  2013-04-30       Impact factor: 3.109

2.  N-Glycan profile analysis of transferrin using a microfluidic compact disc and MALDI-MS.

Authors:  Alessandro Quaranta; Anna Sroka-Bartnicka; Erik Tengstrand; Gunnar Thorsén
Journal:  Anal Bioanal Chem       Date:  2016-04-30       Impact factor: 4.142

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.