Literature DB >> 22698600

Ten-year outcome analysis of off-pump sequential grafting: single surgeon, single center experience.

Shahzad G Raja1, Kareem Salhiyyah, Manoraj Navaratnarajah, Muhammad Umar Rafiq, Jeremy Felderhof, Christopher P Walker, Charles D Ilsley, Mohamed Amrani.   

Abstract

OBJECTIVES: Despite increasing recognition that off-pump coronary artery bypass surgery and sequential grafting strategy individually are associated with improved outcomes, concerns persist regarding the safety and efficacy of combining these 2 techniques. We compared in-hospital and midterm outcomes for off-pump multivessel sequential and conventional coronary artery bypass grafting.
METHODS: From September 1998 to September 2008, 689 consecutive patients received off-pump multivessel sequential coronary artery bypass grafting performed by a single surgeon. These patients were propensity matched to 689 patients who underwent off-pump coronary artery bypass grafting without sequential anastomoses. A retrospective analysis of prospectively collected perioperative data was performed. In addition, medical notes and charts of all the study patients were reviewed. The mean duration of follow-up was 5.1 ± 2.0 years.
RESULTS: The major in-hospital clinical outcomes in the sequential and control groups were found to be similar. After adjusting for clinical covariates, sequential grafting was not an independent predictor of in-hospital adverse events (odds ratio [OR], 1.18; 95% confidence interval [CI], 0.86-1.50; P = .31), medium-term mortality (hazard ratio [HR], 1.26; 95% CI, 1.06-1.32; P = .92), and readmission to hospital (HR, 1.12; 95% CI, 0.96-1.20; P = .80). Sequential grafting was an independent predictor of receiving more than 3 distal anastomoses (OR, 7.46; 95% CI, 4.27-11.45; P < .0001). Risk-adjusted survival was 89% for sequential grafting patients and 88% for conventional grafting patients (P = .96) during the medium-term follow-up.
CONCLUSION: Our analysis confirms the short- and midterm safety and efficacy of off-pump sequential coronary artery bypass grafting.

Entities:  

Mesh:

Year:  2012        PMID: 22698600     DOI: 10.1532/HSF98.20111087

Source DB:  PubMed          Journal:  Heart Surg Forum        ISSN: 1098-3511            Impact factor:   0.676


  3 in total

Review 1.  Off-pump coronary artery bypass grafting: Misperceptions and misconceptions.

Authors:  Shahzad G Raja; Umberto Benedetto
Journal:  World J Methodol       Date:  2014-03-26

Review 2.  Two decades of off-pump coronary artery bypass surgery: Harefield experience.

Authors:  Shahzad G Raja
Journal:  J Thorac Dis       Date:  2016-11       Impact factor: 2.895

3.  Sequential left internal mammary artery grafting in combination with the aortic no-touch technique.

Authors:  Ali Bulut; İlker İnce; Ümit Pınar Sungur; Murat Kurtoğlu; Uğursay Kızıltepe
Journal:  Kardiochir Torakochirurgia Pol       Date:  2022-10-08
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.