Literature DB >> 22698561

Stentless root bioprosthesis for repair of acute type A aortic dissection.

Craig R Smith1, Sotiris C Stamou, Robert L Hooker, Charles C Willekes, John C Heiser, Lawrence H Patzelt, Edward T Murphy.   

Abstract

OBJECTIVE: The superior hemodynamics and excellent long-term clinical performance of stentless xenografts are well described. However, the early and midterm clinical outcomes of stentless valves in patients with acute type A dissection are widely unknown. The current study evaluated the early and midterm clinical outcomes of stentless bioprosthesis for repair of acute type A aortic dissection.
METHODS: Between May 2005 and December 2009, 24 of 80 patients underwent root replacement using the Medtronic Freestyle xenograft (Medtronic Inc, Minneapolis, Minn) at the Meijer Heart Center. Prospective data collection was used for retrospective review. Univariate comparisons of preoperative, intraoperative, and postoperative variables were performed between patients who underwent stentless root bioprosthesis for the correction of acute type A aortic dissection (n = 24).
RESULTS: The mean age of patients was 57 years, with 15 patients aged less than 65 years. Axillary and femoral artery cannulation were used in 16 patients (67%) and 7 patients (29%), respectively. Median crossclamp and cardiopulmonary bypass times were 198 minutes (92-480 minutes) and 288 minutes (109-588 minutes), respectively. Median circulatory arrest time was 28 minutes (24-50 minutes). Operative mortality rate was 25%. Actuarial 5-year survival was 62.5%. No patients required redo aortic root replacement.
CONCLUSIONS: Stentless valve implantation can be accomplished with satisfactory early and midterm clinical outcomes and is a valuable option in patients with acute aortic dissection who require root replacement.
Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22698561     DOI: 10.1016/j.jtcvs.2012.05.029

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  2 in total

1.  Pseudoaneurysm formation after medtronic freestyle porcine aortic bioprosthesis implantation: a word of caution.

Authors:  Brian R Englum; Elizabeth N Pavlisko; Molly C Mack; Asvin M Ganapathi; Matthew A Schechter; Jennifer M Hanna; G Chad Hughes
Journal:  Ann Thorac Surg       Date:  2014-10-07       Impact factor: 4.330

2.  Hospital Results of a Single Center Database for Stentless Xenograft Use in a Full Root Technique in Over 970 Patients.

Authors:  Jerry Easo; Alexander Weymann; Philipp Hölzl; Michael Horst; Harald Eichstaedt; Ahmed Mashhour; Konstantin Zhigalov; Marcin Szczechowicz; Rohit Philip Thomas; Anton Sabashnikov; Otto E Dapunt
Journal:  Sci Rep       Date:  2019-03-13       Impact factor: 4.379

  2 in total