Literature DB >> 2269832

Mechanical properties of human pulleys.

G T Lin1, W P Cooney, P C Amadio, K N An.   

Abstract

In order to determine the mechanical properties of the fibro-osseous pulleys in the hand, the diaphyseal annular pulleys, the volar plate annular pulleys and the cruciate or condensable portions were tested. A custom-made loading device provided proper fit of the soft tissues for a uniform distribution of the pulley load during testing. The A2 pulley was found to be the strongest of the pulleys; the A1 and A4 were the next strongest. The A3 pulley was nearly equal in mean breaking strength to the other annular pulleys, but in absolute breaking load was considerably weaker because of its shortness. The A4 was the least compliant of the pulleys. We concluded that the fibro-osseous A2 and A4 were mechanically stronger and stiffer pulleys than the A1, A3, A5 (volar plate) pulleys. In testing one type of pulley reconstruction, we found that the "belt loop" technique of Karev nearly matched the annular pulleys in strength and energy absorption.

Entities:  

Mesh:

Year:  1990        PMID: 2269832     DOI: 10.1016/0266-7681(90)90085-i

Source DB:  PubMed          Journal:  J Hand Surg Br        ISSN: 0266-7681


  13 in total

Review 1.  [Pulley reconstruction in the hand].

Authors:  M F Langer; S Oeckenpöhler; R Hartensuer; K Herrmann; B Wieskötter
Journal:  Orthopade       Date:  2015-10       Impact factor: 1.087

2.  The flexor tendon pulley system and rock climbing.

Authors:  Timothy P Crowley
Journal:  J Hand Microsurg       Date:  2012-01-18

3.  Trigger finger release with stepwise preservation of the A1 pulley: a functional pulley-preserving technique.

Authors:  Vachara Niumsawatt; David Mao; Stephen Salerno; Warren M Rozen
Journal:  Int Surg       Date:  2013 Oct-Dec

4.  [Hand injuries in mountain sports].

Authors:  K-J Prommersberger; M Mühldorfer-Fodor; K Kalb
Journal:  Unfallchirurg       Date:  2015-06       Impact factor: 1.000

5.  Evaluation of finger A3 pulley rupture in the crimp grip position-a magnetic resonance imaging cadaver study.

Authors:  Thomas Bayer; Werner Adler; Andreas Schweizer; Isabelle Schöffl; Michael Uder; Rolf Janka
Journal:  Skeletal Radiol       Date:  2015-05-02       Impact factor: 2.199

6.  Ultrasound of the digital flexor system: Normal and pathological findings().

Authors:  S Bianchi; C Martinoli; R de Gautard; C Gaignot
Journal:  J Ultrasound       Date:  2007-05-23

7.  A comparative study of A1 pulley compliance.

Authors:  Wen-Lin Tung; Chunfeng Zhao; Yuichi Yoshii; Peter C Amadio; Fong-Chin Su; Kai-Nan An
Journal:  Clin Biomech (Bristol, Avon)       Date:  2010-04-02       Impact factor: 2.063

8.  Development of an In Vitro Swan Neck Deformity Biomechanical Model.

Authors:  Mohammad M Haddara; Stacy Fan; Bogdan A Matache; Shrikant J Chinchalkar; Louis M Ferreira; Nina Suh
Journal:  Hand (N Y)       Date:  2020-10-28

9.  Pollical oblique ligament in humans and non-human primates.

Authors:  Marvin Shrewsbury
Journal:  J Anat       Date:  2003-04       Impact factor: 2.610

10.  Subject-Specific Finite Element Modelling of the Human Hand Complex: Muscle-Driven Simulations and Experimental Validation.

Authors:  Yuyang Wei; Zhenmin Zou; Guowu Wei; Lei Ren; Zhihui Qian
Journal:  Ann Biomed Eng       Date:  2019-12-16       Impact factor: 3.934

View more