Literature DB >> 22695513

Haemolytic anaemia due to stenosed double-reinforced grafts after surgical repaired aortic dissection.

Takeshi Tomiyama1, Yusuke Hosokawa, Hajime Imura, Keiji Tanaka.   

Abstract

Haemolytic anaemia due to a stenosed graft is a rare complication after surgery for aortic dissection. We present the case of a patient with haemolytic anaemia and heart failure, who had undergone emergent ascending aorta replacement for type A acute aortic dissection 5 years earlier. Chest computed tomography revealed severe graft stenosis of the proximal anastomosis and transthoracic echocardiography showed severe aortic regurgitation. Surgical treatment was necessary because of heart failure and myocardial ischaemia due to haemolytic anaemia and aortic regurgitation. During the operation, we found an inner graft surrounded by an outer graft and a dilated lumen between the double-reinforced grafts compressing the inner graft. We successfully reconstructed the aortic root with a total arch replacement. To the best of our knowledge, there are no cases in which haemolytic anaemia and AR developed in a patient with acute aortic dissection surgically treated by such a mechanism.

Entities:  

Mesh:

Year:  2012        PMID: 22695513      PMCID: PMC3422964          DOI: 10.1093/icvts/ivs272

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  4 in total

1.  Repeat surgery for hemolysis 6 years after replacement of the ascending aorta for acute aortic dissection.

Authors:  Satoshi Izumi; Kazutoshi Tano; Kazuya Horike; Nobuyuki Kaihotsu
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2003-09

2.  Supravalvular aortic stenosis after replacement of the ascending aorta.

Authors:  I Vilacosta; A Camino; J A San Román; M J Rollán; R de la Llana; M Gil; L Sánchez Harguindey
Journal:  Am J Cardiol       Date:  1992-12-01       Impact factor: 2.778

3.  Aortic stenosis caused by the felt strip used in repair for acute aortic dissection.

Authors:  Kaoru Matsuura; Hitoshi Ogino; Kenji Minatoya; Hiroaki Sasaki
Journal:  Interact Cardiovasc Thorac Surg       Date:  2004-03

4.  A surgical case for hemolytic anemia after ascending and total arch replacement.

Authors:  Yasushige Shingu; Hidetoshi Aoki; Noriyoshi Ebuoka; Kazuhiro Eya; Ko Takigami; Junichi Oba; Koji Chiba; Takashi Fukuhara
Journal:  Ann Thorac Cardiovasc Surg       Date:  2005-12       Impact factor: 1.520

  4 in total
  2 in total

1.  Haemolytic anaemia resulting from the surgical repair of acute type A aortic dissection.

Authors:  Yuji Sekine; Shin Yamamoto; Takuya Fujikawa; Susumu Oshima; Makoto Ono; Shiro Sasaguri
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-11-07

2.  Usefulness of transesophageal echocardiography in diagnosis of hemolytic anemia post total aortic arch replacement using the elephant trunk technique.

Authors:  Akiko Kumagai; Atsushi Tashiro; Akihiko Abiko; Takeshi Kamada; Hitoshi Okabayashi; Motoyuki Nakamura
Journal:  J Echocardiogr       Date:  2014-08-14
  2 in total