Literature DB >> 22694978

Gross efficiency and cycling economy are higher in the field as compared with on an Axiom stationary ergometer.

William M Bertucci1, Andrew C Betik, Sebastien Duc, Frederic Grappe.   

Abstract

This study was designed to examine the biomechanical and physiological responses between cycling on the Axiom stationary ergometer (Axiom, Elite, Fontaniva, Italy) vs. field conditions for both uphill and level ground cycling. Nine cyclists performed cycling bouts in the laboratory on an Axiom stationary ergometer and on their personal road bikes in actual road cycling conditions in the field with three pedaling cadences during uphill and level cycling. Gross efficiency and cycling economy were lower (-10%) for the Axiom stationary ergometer compared with the field. The preferred pedaling cadence was higher for the Axiom stationary ergometer conditions compared with the field conditions only for uphill cycling. Our data suggests that simulated cycling using the Axiom stationary ergometer differs from actual cycling in the field. These results should be taken into account notably for improving the precision of the model of cycling performance, and when it is necessary to compare two cycling test conditions (field/laboratory, using different ergometers).

Mesh:

Year:  2012        PMID: 22694978     DOI: 10.1123/jab.28.6.636

Source DB:  PubMed          Journal:  J Appl Biomech        ISSN: 1065-8483            Impact factor:   1.833


  5 in total

1.  The Aerodynamics and Energy Cost Assessment of an Able-Bodied Cyclist and Amputated Models by Computer Fluid Dynamics.

Authors:  Pedro Forte; Daniel A Marinho; Ricardo Silveira; Tiago M Barbosa; Jorge E Morais
Journal:  Medicina (Kaunas)       Date:  2020-05-18       Impact factor: 2.430

2.  Rollers Versus Trainers: 10-Km Time Trial.

Authors:  Wayland Tseh; Tate B Devlin; Taylor W Milleson; Tiago V Barreira
Journal:  Int J Exerc Sci       Date:  2017-07-01

3.  Estimation of an Elite Road Cyclist Performance in Different Positions Based on Numerical Simulations and Analytical Procedures.

Authors:  Pedro Forte; Daniel A Marinho; Tiago M Barbosa; Pedro Morouço; Jorge E Morais
Journal:  Front Bioeng Biotechnol       Date:  2020-05-29

4.  Gross and delta efficiencies during uphill running and cycling among elite triathletes.

Authors:  Magnus Carlsson; Viktor Wahrenberg; Marie S Carlsson; Rasmus Andersson; Tomas Carlsson
Journal:  Eur J Appl Physiol       Date:  2020-04-01       Impact factor: 3.078

Review 5.  Sensor-to-Segment Calibration Methodologies for Lower-Body Kinematic Analysis with Inertial Sensors: A Systematic Review.

Authors:  Léonie Pacher; Christian Chatellier; Rodolphe Vauzelle; Laetitia Fradet
Journal:  Sensors (Basel)       Date:  2020-06-11       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.