Literature DB >> 22692522

Depth of focus through different intraocular lenses in patients with different corneal profiles using adaptive optics visual simulation.

Javier Ruiz-Alcocer1, Cari Pérez-Vives, David Madrid-Costa, Santiago García-Lázaro, Robert Montés-Micó.   

Abstract

PURPOSE: To evaluate the depth of focus with monofocal intraocular lenses (IOLs) in patients with different corneal profiles using adaptive optics (AO) visual simulation.
METHODS: An AO visual simulator (crx1, Imagine Eyes) was used to simulate the aberration pattern of three monofocal IOLs (Acrysof IQ SN60WF [Alcon Laboratories Inc]; Akreos Adapt AO [Bausch & Lomb]; and Triplato [AJL Ophthalmic]) of different optic designs. Five groups were considered: patients without any corneal refractive surgery (normal cornea group) and with prior low and high myopic and hyperopic ablations (low myopic ablation, high myopic ablation, low hyperopic ablation, and high hyperopic ablation groups). Defocus curves for all situations were measured, with the target being moved from -5.00 to +2.50 diopters (D) in 0.25-D steps, and visual acuity was measured at all vergences.
RESULTS: Ten eyes from 10 patients were evaluated. The higher residual spherical aberration (SA) for all IOLs was obtained for the high myopic ablation group and the most negative residual SA was obtained for the high hyperopic ablation group. The best compromise between distance visual and depth of focus for the normal cornea, low myopic ablation, and high myopic ablation groups was obtained with the aspheric designs, whereas the best results for the low hyperopic and high hyperopic ablation groups were obtained with the spherical IOL.
CONCLUSIONS: The results of this study suggest that the better compromise between distance visual acuity and depth of focus with the three IOLs and the different corneal profiles relies on a certain amount of positive SA. Above a certain limit of residual SA (positive or negative), visual acuity decreases at all vergences, worsening the depth of focus. Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Year:  2012        PMID: 22692522     DOI: 10.3928/1081597X-20120518-03

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  2 in total

1.  Optical quality of aspheric toric intraocular lenses at different degrees of decentering.

Authors:  Cari Pérez-Vives; Teresa Ferrer-Blasco; David Madrid-Costa; Santiago García-Lázaro; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-04-22       Impact factor: 3.117

2.  Effect of even and odd-order aberrations on the accommodation response.

Authors:  Aikaterini I Moulakaki; Antonio J Del Águila-Carrasco; José J Esteve-Taboada; Robert Montés-Micó
Journal:  Int J Ophthalmol       Date:  2017-06-18       Impact factor: 1.779

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.