Literature DB >> 22689182

Evaluation of integrated positron emission tomography and computed tomography accuracy in detecting lymph node metastasis in patients with adenocarcinoma vs squamous cell carcinoma.

Andrea Billè1, Lawrence Okiror, Andrea Skanjeti, Luca Errico, Vincenzo Arena, Daniele Penna, Francesco Ardissone, Ettore Pelosi.   

Abstract

OBJECTIVES: The aim of our study was to analyze the specificity and sensitivity of integrated positron emission tomography and computed tomography (PET/CT) in detecting nodal metastasis according to histology (adenocarcinoma vs squamous cell carcinoma), and to identify the factors related to false-negative findings.
METHODS: A retrospective, single-institution review of 353 consecutive patients with suspected or pathologically proven, potentially resectable non-small-cell lung cancer (NSCLC) who had integrated PET/CT scanning at the same centre. Lymph node staging was pathologically confirmed on tissue specimens obtained at mediastinoscopy and/or thoracotomy. Statistical evaluation of PET/CT results was performed on a per-patient and per-nodal-station basis.
RESULTS: A total of 2286 nodal stations (1643 mediastinal, 333 hilar and 310 intrapulmonary) were evaluated. Adenocarcinoma was the final diagnosis in 244 patients and squamous carcinoma in 109 patients. Nodes were positive for malignancy in 80 (32.8%) of 244 patients with adenocarcinoma (N1 = 31; N2 = 48 and N3 = 1) and in 32 (29.3%) of 109 with squamous carcinoma (N1 = 21 and N2 = 11). PET/CT in the adenocarcinoma group had a sensitivity, specificity and accuracy of 53.8, 91.5 and 79.1%, and in the squamous cell group, of 87.5, 81.8 and 83.5%, respectively in a per-patient analysis. In the analysis for N2 disease on a per-patient basis, the sensitivity, specificity and accuracy were 38.8, 97.4, and 85.7% for the adenocarcinoma group and 81.8, 91.8 and 90.8% in the squamous cell group. In the adenocarcinoma group, the mean diameter of false-negative lymph nodes was 7 mm (standard deviation [SD] ± 2.5 mm) compared with the diameter of true-positive lymph nodes of 12.5 (SD ± 4 mm; P < 0.00001). In the squamous cell group, the mean diameter of false-negative lymph nodes was 7.4 mm (SD ± 2.8 mm) compared with the diameter of true-positive lymph nodes of 14.7 (SD ± 6 mm; P < 0.005). In the adenocarcinoma group, false-negative lymph nodes were statistically correlated with the presence of vascular invasion and in the squamous cell group only with the maximum standardized uptake value (SUV(max)) < 5.4.
CONCLUSIONS: The sensitivity of PET/CT in detecting nodal metastasis in patients with adenocarcinoma is too low to avoid any further invasive staging procedure. Ultrasound-guided needle biopsy or mediastinoscopy is still necessary in staging patients undergoing lung resection for adenocarcinoma.

Entities:  

Mesh:

Year:  2012        PMID: 22689182     DOI: 10.1093/ejcts/ezs366

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  8 in total

1.  Accuracy of positron emission tomography and computed tomography (PET/CT) in detecting nodal metastasis according to histology of non-small cell lung cancer.

Authors:  David E Smith; Julian Fernandez Aramburu; Alejandro Da Lozzo; Juan A Montagne; Enrique Beveraggi; Agustin Dietrich
Journal:  Updates Surg       Date:  2019-09-24

Review 2.  Imaging the lymphatic system.

Authors:  Lance L Munn; Timothy P Padera
Journal:  Microvasc Res       Date:  2014-06-21       Impact factor: 3.514

3.  Validating guideline concordant care in lung cancer also validates good surgical judgement and skill.

Authors:  Megan K Loo; Anthony W Kim
Journal:  J Thorac Dis       Date:  2018-03       Impact factor: 2.895

4.  Tumor glycolytic heterogeneity improves detection of regional nodal metastasis in patients with lung adenocarcinoma.

Authors:  Kun-Han Lue; Sung-Chao Chu; Ling-Yi Wang; Yen-Chang Chen; Ming-Hsun Li; Bee-Song Chang; Sheng-Chieh Chan; Yu-Hung Chen; Chih-Bin Lin; Shu-Hsin Liu
Journal:  Ann Nucl Med       Date:  2021-11-24       Impact factor: 2.668

5.  Systematic Endobronchial Ultrasound-guided Mediastinal Staging Versus Positron Emission Tomography for Comprehensive Mediastinal Staging in NSCLC Before Radical Radiotherapy of Non-small Cell Lung Cancer: A Pilot Study.

Authors:  Daniel P Steinfort; Shankar Siva; Tracy L Leong; Morgan Rose; Dishan Herath; Phillip Antippa; David L Ball; Louis B Irving
Journal:  Medicine (Baltimore)       Date:  2016-02       Impact factor: 1.889

6.  A nomogram prediction model for recurrent laryngeal nerve lymph node metastasis in thoracic oesophageal squamous cell carcinoma.

Authors:  Yu Liu; Zhi-Qiang Zou; Juan Xiao; Mei Zhang; Lei Yuan; Xiao-Gang Zhao
Journal:  J Thorac Dis       Date:  2019-07       Impact factor: 2.895

7.  Impact of EBUS-TBNA on modalities for tissue acquisition in patients with lung cancer.

Authors:  R J José; P Shaw; M Taylor; D R Lawrence; P J George; S M Janes; N Navani
Journal:  QJM       Date:  2013-11-19

8.  Evaluation of the factors affecting the maximum standardized uptake value of metastatic lymph nodes in different histological types of non-small cell lung cancer on PET-CT.

Authors:  Yuehong Wang; Shanni Ma; Mengjie Dong; Yake Yao; Kanfeng Liu; Jianying Zhou
Journal:  BMC Pulm Med       Date:  2015-03-08       Impact factor: 3.317

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.