Literature DB >> 22682788

Walking ability of children with a hexapod external ring fixator (TSF®) and foot plate mounting at the lower leg.

F Schiedel1, B Vogt, S Wacker, J Pöpping, K Bosch, R Rödl, D Rosenbaum.   

Abstract

Wearing an external fixator for several months can be expected to profoundly affect the ability to walk, but, in principle, full weight-bearing is possible during corrective procedures with the Taylor Spatial Frame (TSF). The present prospective cohort study was conducted to assess whether patients are able to walk with or without crutches during treatment with a TSF on the lower leg. Twenty-four patients (10 girls, 14 boys; average age 11 years, range 6-17) scheduled for fixator surgery with osteotomies in the lower leg and foot mounting were included. Dynamic foot loading during free walking was measured with plantar pressure measurements. The contact area, contact time and contact pressure on the foot plate were recorded and normalized to body weight. In the first postoperative week, all patients needed crutches and 67% showed partial weight-bearing. At the second measurement, about 6 weeks after surgery, 21% of the patients could walk without crutches and 58% were partially weight-bearing with crutches. On the day before fixator removal, 50% of the patients were fully weight-bearing without crutches and 38% were partially weight-bearing, but 12% could not bear any weight or were unable to walk. When a ring fixator is used to correct lower leg deformity and prevent equinus, there is minimal risk of complete dependence and abasia. This study shows that up to 88% of the pediatric patients are able to walk while wearing the fixator. Already a few days after surgery, two-thirds of the patients were partially weight-bearing with crutches, and only 12% needed a wheelchair and were not able to walk with the fixator.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22682788     DOI: 10.1016/j.gaitpost.2012.05.006

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  3 in total

1.  [Spectrum of indications for intramedullary or external fixators for axis correction and limb lengthening].

Authors:  F Schiedel; R Rödl
Journal:  Orthopade       Date:  2013-12       Impact factor: 1.087

2.  The computer-aided parallel external fixator for complex lower limb deformity correction.

Authors:  Mengting Wei; Jianwen Chen; Yue Guo; Hao Sun
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-08-07       Impact factor: 2.924

3.  Patient-reported Outcome and Quality of Life after Treatment with External Fixation: A Questionnaire-based Survey.

Authors:  Shuhei Ugaji; Hidenori Matsubara; Satoshi Kato; Yasuhisa Yoshida; Tomo Hamada; Hiroyuki Tsuchiya
Journal:  Strategies Trauma Limb Reconstr       Date:  2021 Jan-Apr
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.