Literature DB >> 22682711

Are facilities following best practices of pediatric abdominal CT scans?

Amy E Nosek1, Charles W Hartin, Kathryn D Bass, Philip L Glick, Michael G Caty, Merril T Dayton, Doruk E Ozgediz.   

Abstract

BACKGROUND: Established guidelines for pediatric abdominal CT scans include reduced radiation dosage to minimize cancer risk and the use of intravenous (IV) contrast to obtain the highest-quality diagnostic images. We wish to determine if these practices are being used at nonpediatric facilities that transfer children to a pediatric facility.
METHODS: Children transferred to a tertiary pediatric facility over a 16-mo period with abdominal CT scans performed for evaluation of possible appendicitis were retrospectively reviewed for demographics, diagnosis, radiation dosage, CT contrast use, and scan quality. If CT scans were repeated, the radiation dosage between facilities was compared using Student t-test.
RESULTS: Ninety-one consecutive children transferred from 29 different facilities had retrievable CT scan images and clinical information. Half of CT scans from transferring institutions used IV contrast. Due to poor quality or inconclusive CT scans, 19 patients required a change in management. Children received significantly less radiation at our institution compared to the referring adult facility for the same body area scanned on the same child (9.7 mSv versus 19.9 mSv, P = 0.0079).
CONCLUSION: Pediatric facilities may be using less radiation per CT scan due to a heightened awareness of radiation risks and specific pediatric CT scanning protocols. The benefits of IV contrast for the diagnostic yield of pediatric CT scans should be considered to obtain the best possible image and to prevent additional imaging. Every facility performing pediatric CT scans should minimize radiation exposure, and pediatric facilities should provide feedback and education to other facilities scanning children.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22682711     DOI: 10.1016/j.jss.2012.05.036

Source DB:  PubMed          Journal:  J Surg Res        ISSN: 0022-4804            Impact factor:   2.192


  8 in total

1.  Quality of pediatric abdominal CT scans performed at a dedicated children's hospital and its referring institutions: a multifactorial evaluation.

Authors:  Aisling Snow; Carly E Milliren; Dionne A Graham; Michael J Callahan; Robert D MacDougall; Richard L Robertson; George A Taylor
Journal:  Pediatr Radiol       Date:  2017-01-13

2.  Boots on the ground: how to influence your local radiology departments to use appropriate CT dose.

Authors:  Thomas L Slovis
Journal:  Pediatr Radiol       Date:  2014-10-11

3.  Development of pediatric CT protocols for specific scanners: why bother?

Authors:  Dianna D Cody
Journal:  Pediatr Radiol       Date:  2014-10-11

4.  Time to Appendectomy and Risk of Complicated Appendicitis and Adverse Outcomes in Children.

Authors:  Stephanie K Serres; Danielle B Cameron; Charity C Glass; Dionne A Graham; David Zurakowski; Mahima Karki; Seema P Anandalwar; Shawn J Rangel
Journal:  JAMA Pediatr       Date:  2017-08-01       Impact factor: 16.193

5.  Working Face-to-Face for Pediatric CT Dose Reduction: A Community Toolkit.

Authors:  Diane Armao; Terry Hartman; Christopher M Shea; Cassandra Sams; Lynn Ansley Fordham; J Keith Smith
Journal:  Diagn Imaging Eur       Date:  2016-10

6.  A Toolkit for Pediatric CT Dose Reduction in Community Hospitals.

Authors:  Diane Armao; Terry Hartman; Christopher M Shea; Cassandra Sams; Marija Ivanovic; Lynn Ansley Fordham; J Keith Smith
Journal:  J Am Coll Radiol       Date:  2016-06-09       Impact factor: 5.532

Review 7.  Pediatric Exposures to Ionizing Radiation: Carcinogenic Considerations.

Authors:  Kristy R Kutanzi; Annie Lumen; Igor Koturbash; Isabelle R Miousse
Journal:  Int J Environ Res Public Health       Date:  2016-10-28       Impact factor: 3.390

8.  Assessment of radiation protection awareness and knowledge about radiological examination doses among Italian radiographers.

Authors:  F Paolicchi; F Miniati; L Bastiani; L Faggioni; A Ciaramella; I Creonti; C Sottocornola; C Dionisi; D Caramella
Journal:  Insights Imaging       Date:  2015-11-23
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.