Literature DB >> 22681242

Device-related infective endocarditis, with special consideration of implanted intravascular and cardiac devices in a predominantly male population.

Ingrid L Roig1, Rabih O Darouiche, Daniel M Musher, Barbara W Trautner.   

Abstract

BACKGROUND: The relationship between invasive medical devices and infective endocarditis (IE) has not been comprehensively assessed. We describe our experience of patients with IE, with particular attention to the role of pre-existing intravascular catheters and implanted cardiac devices in the pathogenesis.
METHODS: We performed a retrospective review of hospital records over a 10-y period (1997-2007), and included patients with 'definite' or 'possible' IE as per the modified Duke criteria. The complete electronic medical record was reviewed for the presence of intravascular devices prior to the onset of IE, including intravascular catheters and implanted cardiac devices (defibrillators and pacemakers).
RESULTS: We identified 155 patients with IE. Infection involved a native valve in 124 (80%) patients and a prosthetic valve in 15 (9.7%). In the remaining 16 (10.3%) patients, infection was attributed to an implanted cardiac device. The most commonly identified source of infection was a central venous catheter, accounting for 17.4% of patients, followed by an implanted cardiac device in 10.3% of patients. Staphylococcus aureus was the most commonly isolated organism in catheter-associated IE and cardiac device-associated IE (31.9% and 62.5%, respectively). Thirty-five (22.5%) patients died within 90 days. Mortality was 31.9% in patients with IE caused by methicillin-resistant S. aureus (MRSA).
CONCLUSIONS: Intravascular catheters and cardiac implantable devices are common sources of infection leading to IE, and the intracardiac devices themselves often become infected, with MRSA as the predominant pathogen.

Entities:  

Mesh:

Year:  2012        PMID: 22681242     DOI: 10.3109/00365548.2012.678882

Source DB:  PubMed          Journal:  Scand J Infect Dis        ISSN: 0036-5548


  5 in total

1.  In Vitro and In Vivo Effectiveness of an Innovative Silver-Copper Nanoparticle Coating of Catheters To Prevent Methicillin-Resistant Staphylococcus aureus Infection.

Authors:  Myriam K S Ballo; Sami Rtimi; César Pulgarin; Nancy Hopf; Aurélie Berthet; John Kiwi; Philippe Moreillon; José M Entenza; Alain Bizzini
Journal:  Antimicrob Agents Chemother       Date:  2016-08-22       Impact factor: 5.191

Review 2.  The causative agents in infective endocarditis: a systematic review comprising 33,214 cases.

Authors:  Christiana T Vogkou; Nikolaos I Vlachogiannis; Leonidas Palaiodimos; Antonis A Kousoulis
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2016-05-11       Impact factor: 3.267

Review 3.  Staphylococcus aureus infections: epidemiology, pathophysiology, clinical manifestations, and management.

Authors:  Steven Y C Tong; Joshua S Davis; Emily Eichenberger; Thomas L Holland; Vance G Fowler
Journal:  Clin Microbiol Rev       Date:  2015-07       Impact factor: 26.132

4.  Molecular characterization of endocarditis-associated Staphylococcus aureus.

Authors:  Cara Nethercott; Amanda N Mabbett; Makrina Totsika; Paul Peters; Juan C Ortiz; Graeme R Nimmo; Geoffrey W Coombs; Mark J Walker; Mark A Schembri
Journal:  J Clin Microbiol       Date:  2013-04-24       Impact factor: 5.948

5.  Clinical manifestations of lead-dependent infective endocarditis: analysis of 414 cases.

Authors:  A Polewczyk; M Janion; R Podlaski; A Kutarski
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2014-05-03       Impact factor: 3.267

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.