Literature DB >> 22677368

Robustness against interfraction prostate movement in scanned ion beam radiation therapy.

Urszula Jelen1, Filippo Ammazzalorso, Marie-Anne Chanrion, Sebastian Gräf, Klemens Zink, Rita Engenhart-Cabillic, Andrea Wittig.   

Abstract

PURPOSE: To assess the robustness of scanned ion beam treatment plans against the interfraction internal target motion and evaluate the limits of validity of target-based isocenter realignment for prostate cancer radiation therapy. METHODS AND MATERIALS: For 12 prostate patients, scanned beam carbon ion treatment plans were prepared using 2 lateral opposed beams and the raster scanning technique with different clinical target volume (CTV) to planning target volume (PTV) margins (2-10 mm). Internal target motion of 2-15 mm in anteroposterior (AP), superoinferior (SI), and left-to-right (LR) directions was simulated by displacing the CTV contours with respect to the computed tomography data. The plans were recalculated with and without target-based isocenter realignment and the CTV coverage was assessed.
RESULTS: For CTV shifts within the applied planning margin, the CI-98% is greater than 98.0%, both with and without isocenter realignment. Without realignment, because of the sharp lateral gradients, the CI-98% shows rapid fall as soon as the target shift exceeds the applied planning margin for all displacement directions. With isocenter realignment, the coverage improves notably for shifts in AP and SI directions and the CI-98% is restored to >95.0% for plans optimized with a 2-mm margin, >97% with a 3-mm margin, and >98% with larger margins. For large corrections, predominately in AP direction, cold spots in the CTV may occur. Their magnitude is dependent on the patients' individual anatomies.
CONCLUSIONS: Within the physiological limits of internal prostate movement, target-based isocenter realignment results in improved CTV coverage for shifts in AP and SI directions exceeding the applied planning margin. Assuming optimal patient setup reproducibility (eg, immobilization, setup error correction, patient preparation protocols), hence negligible interfraction bone and soft-tissue variations, changes in traversed densities resulting from target-based realignment applied with a reduced planning margin do not induce significant dose deterioration in most of the cases.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22677368     DOI: 10.1016/j.ijrobp.2012.03.058

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  2 in total

1.  Dosimetric robustness against setup errors in charged particle radiotherapy of skull base tumors.

Authors:  Filippo Ammazzalorso; Urszula Jelen; Rita Engenhart-Cabillic; Wolfgang Schlegel
Journal:  Radiat Oncol       Date:  2014-12-05       Impact factor: 3.481

2.  Probabilistic dose distribution from interfractional motion in carbon ion radiation therapy for prostate cancer shows rectum sparing with moderate target coverage degradation.

Authors:  Daniel Bridges; Hidemasa Kawamura; Tatsuaki Kanai
Journal:  PLoS One       Date:  2018-08-31       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.