Literature DB >> 22673003

A vibrational technique for diagnosing loosened total hip endoprostheses: an experimental sawbone study.

Johannes Sebastian Rieger1, Sebastian Jaeger, Christian Schuld, Jan Philippe Kretzer, Rudi Georg Bitsch.   

Abstract

Aseptic loosening of hip implants is a severe orthopaedic problem and a valid diagnosis is often difficult. A potential method to determine loosening of the prosthesis is a swing analysis of the bone-implant interface using a vibrational technique. In this study, hip models were constructed to assess the vibration behaviour of the stem and cup components. Four different states of implant loosening were simulated: (1) stem and cup stable, (2) stem loosened and cup stable, (3) stem and cup loosened, and (4) stem stable and cup loosened. The model was excited at the lateral condyle of the femur between 100 Hz and 2000 Hz. Resonance spectra were recorded using an optical laser vibrometer and an accelerometer-based system. Analysis of the spectra revealed shifts of the resonances towards lower frequencies, especially in the case of a loosened stem component. The integral value of the spectra was a second parameter that was sensitive to a stem loosening. In the case of a loosened cup, a peak count analysis resulted in a significantly higher number of counts. In our model, different states of implant loosening could be determined with a vibrational technique and the localisation of the loosened component could be distinguished as well.
Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

Mesh:

Substances:

Year:  2012        PMID: 22673003     DOI: 10.1016/j.medengphy.2012.05.007

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  4 in total

1.  Ex Vivo Evaluation of Cementless Acetabular Cup Stability Using Impact Analyses with a Hammer Instrumented with Strain Sensors.

Authors:  Antoine Tijou; Giuseppe Rosi; Philippe Hernigou; Charles-Henri Flouzat-Lachaniette; Guillaume Haïat
Journal:  Sensors (Basel)       Date:  2017-12-27       Impact factor: 3.576

2.  Knee Implant Loosening Detection: A Vibration Analysis Investigation.

Authors:  Arash Arami; Jean-Romain Delaloye; Hossein Rouhani; Brigitte M Jolles; Kamiar Aminian
Journal:  Ann Biomed Eng       Date:  2017-10-24       Impact factor: 3.934

Review 3.  Altering the Course of Technologies to Monitor Loosening States of Endoprosthetic Implants.

Authors:  João Henrique Cachão; Marco P Soares Dos Santos; Rodrigo Bernardo; António Ramos; Rainer Bader; Jorge A F Ferreira; António Torres Marques; José A O Simões
Journal:  Sensors (Basel)       Date:  2019-12-23       Impact factor: 3.576

4.  Multiscale Sensing of Bone-Implant Loosening for Multifunctional Smart Bone Implants: Using Capacitive Technologies for Precision Controllability.

Authors:  Inês Peres; Pedro Rolo; Jorge A F Ferreira; Susana C Pinto; Paula A A P Marques; António Ramos; Marco P Soares Dos Santos
Journal:  Sensors (Basel)       Date:  2022-03-25       Impact factor: 3.576

  4 in total