Literature DB >> 22672896

Effective marker placement for functional identification of the centre of rotation at the hip.

S Kratzenstein1, E I Kornaropoulos, R M Ehrig, M O Heller, B M Pöpplau, W R Taylor.   

Abstract

The accuracy and precision of quantifying musculoskeletal kinematics, and particularly determining the centre of rotation (CoR) at the hip joint, using skin marker based motion analysis is limited by soft tissue artefact (STA). We posed the question of whether the contribution of individual markers towards improving the precision of the functional joint centre using marker based methods could be assessed, and then utilised to allow effective marker placement for determination of the CoR at the hip. Sixty-three retro-reflective skin markers were placed to encompass the thighs of seven healthy subjects, together with a set of sixteen markers on the pelvis. The weighted optimal common shape technique (wOCST) was then applied to determine the weighting, or importance, of each marker for identifying the centre of rotation at the hip. The markers with the highest weightings over all subjects and measurements were determined that identified the HJC with the highest precision. The use of six markers in selected regions (two anterior, two lateral and two posterior) allowed the HJC to be determined with a similar precision to the complete set of 63 markers, with the determined regions predominantly distant from the hip joint, excluding areas associated with the bellies of large muscles and therefore large motion artefact from muscle activity. The novel approach presented here allows an understanding of each marker's contribution towards a precise joint determination, and therefore enables the targeted placement of markers for reliable assessment of musculoskeletal kinematics.
Copyright © 2012 Elsevier B.V. All rights reserved.

Mesh:

Year:  2012        PMID: 22672896     DOI: 10.1016/j.gaitpost.2012.04.011

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  6 in total

1.  Modifications of femoral component design in multi-radius total knee arthroplasty lead to higher lateral posterior femoro-tibial translation.

Authors:  Tilman Pfitzner; Philippe Moewis; Patrick Stein; Heide Boeth; Adam Trepczynski; Philipp von Roth; Georg N Duda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-06-27       Impact factor: 4.342

2.  Comparison of the kinematics and kinetics of shoulder exercises performed with constant and elastic resistance.

Authors:  Ramona Häberle; Florian Schellenberg; Renate List; Michael Plüss; William R Taylor; Silvio Lorenzetti
Journal:  BMC Sports Sci Med Rehabil       Date:  2018-11-28

3.  The Effect of Ankle Bracing on Kinematics in Simulated Sprain and Drop Landings: A Double-Blind, Placebo-Controlled Study.

Authors:  Alison N Agres; Marios Chrysanthou; Peter C Raffalt
Journal:  Am J Sports Med       Date:  2019-05       Impact factor: 6.202

4.  Evaluation of functional methods of joint centre determination for quasi-planar movement.

Authors:  Lin Meng; Craig Childs; Arjan Buis
Journal:  PLoS One       Date:  2019-01-17       Impact factor: 3.240

5.  Soft tissue artefacts of the human back: comparison of the sagittal curvature of the spine measured using skin markers and an open upright MRI.

Authors:  Roland Zemp; Renate List; Turgut Gülay; Jean Pierre Elsig; Jaroslav Naxera; William R Taylor; Silvio Lorenzetti
Journal:  PLoS One       Date:  2014-04-18       Impact factor: 3.240

6.  Validation of a Novel Device for the Knee Monitoring of Orthopaedic Patients.

Authors:  Mahmut Enes Kayaalp; Alison N Agres; Jan Reichmann; Maxim Bashkuev; Georg N Duda; Roland Becker
Journal:  Sensors (Basel)       Date:  2019-11-27       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.