Literature DB >> 22672847

Comparison of GC/MS and LC/MS methods for the analysis of propofol and its metabolites in urine.

Sun Young Lee1, Na-Hyun Park, Eun-Kyung Jeong, Jae-Woo Wi, Chang-Ju Kim, Jin Young Kim, Moon Kyo In, Jongki Hong.   

Abstract

Gas chromatography-mass spectrometry (GC/MS) and liquid chromatography-mass spectrometry (LC/MS) were compared for their capacity to metabolite identification, sensitivity, and speed of analysis for propofol and its metabolites in urine samples. Acidic hydrolysis, liquid-liquid extraction (LLE), and trimethylsilyl (TMS) derivatization procedures were applied for GC/MS analysis. The LC/MS analysis used a simple sample pretreatment based on centrifugation and dilution. Propofol and four metabolites were successfully analyzed by GC/MS following TMS derivatization. One compound, di-isopropanolphenol was tentatively characterized as a new metabolite observed for the first time in human urine. The TMS derivatization greatly improved the chromatographic properties and detection sensitivity, especially for hydroxylated metabolites. The lower limits of quantitation (LLOQ) of propofol were about 325 and 0.51 ng/mL for the GC/MS scan mode and selected ion monitoring (SIM) mode, respectively. In addition, five conjugated propofol metabolites were successfully analyzed by LC-MS/MS in negative ion mode. The detection sensitivity for these conjugated metabolites could be greatly enhanced by the addition of triethylamine to the mobile phase without any loss of LC resolution capacity. The LLOQs of propofol-glucuronide (PG) were about 1.17 and 2.01 ng/mL for the LC-MS-selected ion monitoring (SIM) and multiple reaction monitoring (MRM) mode, respectively. Both GC/MS and LC/MS methods sensitively detected nine metabolites of propofol and could be used to provide complementary data for the reasonable propofol metabolism study. Urinary excretion profiles for propofol and its metabolites following administration to human were suggested based on the total ion chromatograms obtained by GC/MS and LC/MS methods, respectively.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22672847     DOI: 10.1016/j.jchromb.2012.05.011

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  3 in total

Review 1.  Novel methodologies in analysis of small molecule biomarkers and living cells.

Authors:  Yinan Chen; Zhenggang Zhu; Yingyan Yu
Journal:  Tumour Biol       Date:  2014-08-14

2.  Selective and Accurate Determination Method of Propofol in Human Plasma by Mixed-Mode Cation Exchange Cartridge and GC-MS.

Authors:  Jae Sung Pyo
Journal:  J Anal Methods Chem       Date:  2016-08-11       Impact factor: 2.193

Review 3.  Propofol detection for monitoring of intravenous anaesthesia: a review.

Authors:  David C Ferrier; Janice Kiely; Richard Luxton
Journal:  J Clin Monit Comput       Date:  2021-07-02       Impact factor: 1.977

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.